WARNING
The Seastar is an industrial product designed for use in rugged underwater
environments. The Seastar installation and power system should be designed by
a qualified engineer and installed by qualified technicians.
3.1.
Mounting
Figure 3 shows the outline of the Seastar. If an ROS provided mounting kit is not used, the Seastar may be
mounted by clamping the body of the light or using the three, 10-32 holes in the end bell. It is not recommended
to clamp to the bezel of the light.
3.2.
Electrical
The Seastar pinout will depend on customer selections; Figure 4 shows the default wiring. The ground pin should
be wired to earth ground.
WARNING
The Seastar should be operated only through a circuit with ground fault
interrupt protection.
REM OTE OCEAN SYSTEM S CLAI M S PROPRI ETARY RI GHTS TO THE
I NFORM ATI ON DI SCLOSED HEREI N. THI S DOCUM ENT I S FURNI SHED I N
CONFI DENCE ON THE EXPRESS UNDERSTANDI NG THAT NEI THER I T NOR
ANY REPRODUCTI ON THEREOF W I LL BE DI SCLOSED TO OTHERS OR
USED FOR THE PURPOSE OF M ANUFACTURE OR PROCUREM ENT.
APPROVED FOR I NTERNAL RELEASE ONLY. DI STRI BUTI ON I S LI M I TED.
NOTES: UNL ESS OTHERW ISE SPECIFIED
1. M ATERIAL :
HOUSING: AL UM INUM 60 6 1 -T6
END BELL: ALUM INUM 7075-T6
BEZEL: ALUM INUM 6061-T6
W INDOW : PL EXIGL AS G
2 . FINISH: HARD ANODIZE, BL ACK
3 . DEPTH RATING
: 2 0 ,0 0 0 ft (6 k m ) SEAW ATER
4 . W EIGHT AIR / W ATER:
SPOT: 1.9 / 1 .0 lb (.
8 6 / .4 5 k g )
FL OOD: 1 .8 / .91 lb
(.8 1 / .4 1 k g )
5 . M INIM UM L IGHT O
UTPUT:
SPOT: 9,000 lx
FLOOD: 3,600 lx , 10,000 lm
6 . BEAM ANGL E AT 5 0 % INTENSITY
SPOT: 38 °
FLOOD: 110
°
7 . OPERATIONAL TEM P: 4 0 ° C. SEL F-DIM M ING THERM AL PROTECTION ABOVE 4 0 °C
8 . POW ER:
120 VAC, 1.0 A
24 VDC, 4 .6 A
9 . DIM M ING OPTIONS:
AC: PHASE CUT DIM M ING
DC: RS4 8 5 , 0 - 5 V, 0 - 1 0 V
10. DEPENDING ON CUSTOM ER SEL ECTABL E CONNECTOR.
C
B
A
A
B
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
C
D
SHEET 1 O F 2
SCALE: NO NE
REV
DWG . NO .
D
SI ZE
TI TLE:
1+
CAG E
10-01314
NEXT ASSY
USED O N
2T637
D
APPRO VALS
APPLI CATI O N
APPRO VED
M . POGUE
APPRO VED
CHECKED
DRAW N
DATE
UNLESS O THERW I SE SPECI FI ED
DI M ENSI O NI NG AND TO LERANCI
NG I AW ASM E Y14. 5 2009
•
DI M ENSI O NS ARE I N I NCHES
•
TO LERANCES: ANG LES
±1°
•
. XXX
±. 005
. XX
±. 01
.X
±. 03
REM O VE BURRS AND BREAK SHARP
EDG ES . 015 M AX
•
UNSPECI FI ED RADI I . 015 M AX
•
M ACHI NE TO O L M I SM ATCH . 00
3 M AX
•
SURFACE TEXTURE: 63
•
SEASTAR - INSTALLATION AND
OUTLINE
17OCT19
PROTOTYPE
REVISIONS
REV
DESCRIPTION
EC NO.
DATE
APPROVED
Ø 3.31
3.31 FLOOD
3.55 SPOT
1.375
Ø 3.05
1.66
2.00
Ø3X 10-32 UNF - 2B .25 DEEP
DEPENDING ON
CONNECT OR
Figure 3. Installation Outline
1
EARTH GROUND
2
120 V A C, 1P, 1.5 A S UP P LY
3
120 VAC RETURN / NE UTRA L
AC WIRING
1
EARTH GROUND
2
24 VDC, 5 A SUPPLY
3
24 VDC RETURN
DC SERIAL
4
RS 485 +
5
RS 485 -
1
EARTH GROUND
2
24 VDC, 4 A SUPPLY
3
24 VDC RETURN
0 - 10 (0 - 5) V DIMMING
4
0-10 (0-5) V +
5
0-10 (0-5) V -
Figure 4. Sample Wiring