CHAPTER 2 – INSTALLATION, WARNINGS
7
A:
Attach the machine base plate to the work table by means of three M8
screws or a clamp.
B:
Fit the machine into the base plate shaft until resting on the base, and
firmly tighten the M10 threaded rod with a 5 mm. ALLEN wrench.
C:
Connect the machine to a
SINGLE phase socket (220 V supply) with
ground wire and switch on the main socket.
D:
Arm balance
:
Regulate the tightness of the internal damper if the
arm tends to descend too far or has too much ascending
strength. By t
urning the regulating ALLEN screw on its different
positions, different weights at the arm end are balanced:
- Position
-
:
Minimum tension
-
Position
–
:
Middle tension
-
Position
—
:
Maximum tension
IMPORTANT:
WARNINGS
The use and operation of the machine involve certain risks and precautions that have to be taken
into account by the operator in order to preclude the occurrence of serious injuries.
1.- The variator board is designed to start the 3 phases High Frecuency motor.
Do not
connect the motor directly to a 220 V. source of electric current
.
2.-
Do not alter the machine structure or motor component.
Any additional work at the
machine, installation or improper handling may suppose the immediate lost of its warranty.
3.- Be careful with the dress accessories and others such as long hair, gloves and jewellery.
4.-
Always use eye-protective glasses
when operating the machine
5.-
Don’t insert
your fingers into the vicinity of the head stop when the arm is
nearing its most raised position.
6.-
Don’t put
your hand in the area below the lifter sheath (see page 6) when
repositioning this latter in its lowest position (lowering).
Before making any manipulation to the machine, for verification, manipulation, repair or
maintenance,
you must disconnect the machine from the power supply.
●
Motor Supply voltage: 200-240 V. 50/60 Hz.;
●
Machine Power: 0,55 Kw.
●
Maximum Voltage Supply: V
máx
.= 240 V.
●
The socket must have a ground wire and differential 300 mA.
Avoid
current fluctuations.
- Operating Environment:
Use the inverter within the ambient temperature range from -10 ºC. to
+50ºC. / Relative Humidity: 5 a 95% (no condensation).
- Atmosphere:
Avoid exposing the inverter to dust, direct sunlight, corrosive gases, flammable gas,
oil mist, vapour or water drops. Do not submit the inverter to sudden changes of temperature that
may cause condensation.
Summary of Contents for MOSQUITO
Page 20: ...20 ...
Page 23: ...CHAPTER 8 WORKING AREAS ROSCAMAT MOSQUITO vertical 23 ...
Page 24: ...CHAPTER 8 WORKING AREAS ROSCAMAT MOSQUITO V H Vert Horizontal 24 ...
Page 25: ...CHAPTER 8 MACHINE SECTION 25 ...
Page 27: ...CHAPTER 8 ELECTRICAL DIAGRAM CONNECTIONS 27 ...
Page 28: ...CHAPTER 8 ELECTRICAL DIAGRAM CONNECTIONS AUT LUBRICATION 28 ...
Page 29: ...CHAPTER 8 NOTES 29 DATE DESCRIPTION Date of creation September 2009 ...