94
Orion X Installation and Operations Manual
To create a new switch macro, proceed as follows:
1. Open a new switch macro by clicking on the
New
icon in the Presets column of the working area. A
prompt will be displayed asking whether the existing connections should be adopted for the new switch
macro.
2. Double click in the
Full Access
,
Video Only
or
Private Mode
columns to select the switching
operations desired, or use the function for a disconnect (
Disconnect CPU
).
3. Save the switch macro by clicking the
Save
icon in the Presets column of the working area. A save
dialog will be opened.
4. Enter a name for the new switch macro and confirm by clicking the
Ok
button in the save dialog.
5. By clicking on a selected switch macro with the right mouse button, a copy of the current switch macro
can be created using the
Save as...
option.
6. Macros can be deleted by selecting them and clicking the
Delete
icon.
To load a switch macro to the matrix, proceed as follows:
1. Select the switch macro to be loaded in the Presets column of the working area.
2. Activate the selected macro by clicking the
Send
button below the Presets column.
Notes:
A predefined switch macro can only be activated in when the Java Tool is in online mode.
Only switch macros that are hardware and current configuration compliant can be executed.
Serial Interface
The Orion X allows switching via a serial interface (RS232).
Detailed information for the serial interface and the corresponding switching commands are available in form of
an API document (application programming interface) upon request.
Power Up and Power Down Functions
This section deals with Power functions of the Orion X.
Restart
The Orion X can be restarted through the OSD and the Java Tool.
Restarting Through the OSD
1. Select
Configuration > Restart Matrix
or
Restart IO Board
in the main menu to restart either the
matrix or I/O boards.
2. Confirm the selection with
Okay
button.
The matrix or I/O boards will be restarted with the current settings.
Restarting through the Java Tool
Select
Matrix > Advanced Service > Restart Matrix
in the menu bar.
The Orion X will be restarted with the current settings.
Note:
The boot process of the matrix might take longer if no physical network connection is available.