Orion X Installation and Operations Manual
79
Preparation
Take the following steps in order to prepare for the matrix update:
1. Save the matrix configuration externally.
2. Open
Extras > Options
in the menu bar, and enter the path to the firmware update files in the
Firmware Directory
setting. Click the
Okay
button to confirm the path.
3. Put any spare boards into unused slots in the matrix.
4. If the Syslog function has been unlocked with a license key, activate it to monitor the update.
Ensure that all USB 2.0 extenders are only connected to their assigned ports (fixed ports) before the matrix
update is started, or the stability of the update may be affected.
Performing the Update
To perform the matrix update, proceed as follows:
1. Select
Administration > Update Matrix Firmware
in the task area. All updateable components of the
matrix will be automatically selected and highlighted in green
Figure 73. Matrix Update through the Java Tool
2. Start the update by clicking the
Update
button.
3. Restart the Matrix after the update by pressing the
Reload
button in the lower part of the working area.
For a complete initialization of the matrix, a cold start (power cycle) is recommended.