ENGINEERING STANDARDS
Rosedale Products Inc.
3730 west liberty Road
Ann Arbor, MI 48103
IOM
7_4_27 Model CR8.DOC
N:\IOM\
Issue Date: 01MAY01
Revision: D
Revision Date: 24APR2015
Specification No.
7.4.27
Page 9 of 14
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Rosedale Engineering Standards are the property of Rosedale Products, Inc. A Rosedale Standard or copy thereof shall no be distributed (except with express approval of
Rosedale Products, Inc.) to any individual or firm beyond the intended recipient firm or individual. Firms of individuals acting contrary to the above may be subject to
suit, ineligibility for continued or future employment, or removal from Rosedale’s “Approved Manufacturers and Specialty Contractors List”.
7. Remove debris and sludge from inside the inlet portion of housing to avoid
interference with cover seal or flow of fluid being filtered.
8. Install new filter cartridge. Make sure the cartridge is fully seated into the
cartridge pedestal.
10. Inspect cover gasket for cuts or other signs of failure and make sure it is properly
seated.
11. Move cover back into position, Install cover by turning clockwise till seated on
the o-ring. Once initial contact with o-ring occurs, tighten approximately one half
turn. The application of process fluid (to wet seal) or lubricant will make it easier to
install cover for a sufficient seal.
Your Rosedale Model CR8135 Filter unit is now ready for operation. Refer to Filter System Start-up
Procedure.