INSTALLATION, OPERATION, & MAINTENANCE MANUAL
Rosedale Engineering Standards are the property of Rosedale Products, Inc. A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale
Products, Inc.) to any individual or firm beyond the intended recipient firm or individual. Firms of individuals acting contrary to the above may be subject to suit, ineligibility for continued or
future employment, or removal from Rosedale’s "Approved Manufacturers and Specialty Contractors List".
I.
Installation
Please remove all shipping and crating materials carefully. Be sure to remove the plugs from the inlet and
outlet openings. Dispose of all crating materials safely.
The
MODEL LCO-8
Filter unit is capable of having several different piping variations based upon the outlet
style of your unit. The inlet service line should be connected to the inlet NPT coupling located near the top of
the unit (above the basket level).
The outlet service line should be connected to the outlet NPT coupling, located near the middle or bottom of the
unit (below the basket level). The
MODEL LCO-8
is designed to utilize either the side NPT coupling as an
outlet or the bottom NPT coupling as an outlet, depending upon your application requirement. Simply install
the NPT plug to direct flow as needed.
There are two 1/4" NPT ports on the shell of the
MODEL LCO-8
Filter unit. These ports can remain plugged
or used for pressure gauges or special fittings as your application requires.
Some installations require electrical grounding of all equipment, be sure to provide adequate grounding where
necessary.
After completing installation be sure to double check connections for integrity. Your
MODEL LCO-8
Filter
unit has been factory pressure tested leak free, therefore, any seepage problems usually occur from improper
installation connections.
You are now ready to install the filter basket and bag. Remove cover by loosening the T-bolt clamp sufficiently
to allow removal of the clamp assembly.
Place the basket into the filter housing, make sure the basket flange is firmly seated onto the step on the inside
of the housing.
Insert bag into the bag basket making sure filter bag ring is firmly seated against the top of the basket flange.
For best results, be sure filter bag is installed fully extended to the bottom of the basket.
Before replacing cover and clamp assembly, inspect cover seal gasket (replacing as necessary). Replace cover
and tighten the T-bolt clamp assembly to ensure a leak proof seal between the cover and housing body.
Your Rosedale
MODEL LCO-8
is now ready for operation!