SLF 2250/4000
Hydromatic Stinger
Page - 35 -
© 2014
Technical Description
Switches and indications on the pump control panel
J25
water tank drain valve
J87hl foam proportioning valve for left rapid intervention system
J87s
foam proportioning valve for the RM 65 C stinger turret
J87t
foam proportioning valve for the RM 60 C roof turret
J164/1
water side manometer drain / flush valves
J164/2
foam side manometer drain / flush valves
N7
rear display - for further information please see next pages
N11
display for camera and infra-red camera on the stinger
P28
normal pressure gauge: indicates system water pressure on
the discharge side of the water pump
P29
foam compound pressure gauge: indicates system foam
compound pressure on the discharge side of the foam
compound pump
P30
water pressure / vacuum gauge: indicates supply pressure
of hydrant / nurse truck (black sector) or vacuum (red
sector)
P31
foam compound pressure / vacuum gauge: indicates supply
pressure of foam pump / nurse truck (black sector) or
vacuum (red sector)
S712 potentiometer: volume control of radio loudspeaker
U31
Roof turret´s remote control - for further information please
refer to the "Roof Turret Operation" chapter in this manual
Y_
pneumatic solenoids - for further information please refer
to the "Pneumatic Installation" chapter in this manual
U31
J162/1
Y_
J164/2
J87hr
J87t
J87s
P31
P30
P29
P28
S712
N7
N11
J25