Stinger and Stinger Turret Operation
Description of the radio remote control unit
The boom and the turret is controlled via radio remote control.
The switches for turret control are integrated in boom´s remote
control.
The turret can be also controlled from the light mast remote
control.
P63
display of the remote control
S2a
switch: P.T.O. ON / OFF
S6
switch: foam operation ON / OFF
S9
switch: pump speed increase / decrease
S33
switch: engine start / stop
S48
switch: flow 50% / 100%
S50
switch: water toggle / HFO (hands free operation)
S220 switch: powder ON / OFF *
S261 main switch and/or emergency stop switch
S294 switch: start / frequency
S296 switch: auto level
S478 switch: high attack position / low attack position
S486 switch: auto stow / fast attack position
S487 switch: piecing tool ON / OFF
S489 Joystick of turret RM 65C / piercing tool
S517 switch: piercing tool penetaration
S530 Joystick of boom
Sx
switch: not in use
N11
Display and accumulator for singer camera - for further
information please refer tot he separate operation manual
For further information please refer to separate operation manual.
CAUTION !
Sight contact with the turret is absolutely essential!
Never point the discharge jet at anybody.
DANGER OF INJURY TO PERSONNEL!
S294 S33 S2a
S9 S296
P63
S220 S6
S48 S50
S489
S261 S478
S517 S487 Sx S486
S530
N11