Page - 72 -
© 2014
SLF 2250/4000
Hydromatic Stinger
Roof Turret Operation
Description of the radio remote control unit of the RM 60 C
The remote control unit is stowed in the pump compartment.
1
switch: roof turret turn to the left
2
switch: roof turret turn to the right
3
switch: lower roof turret
4
switch: raise roof turret
5
switch: roof turret deflector adjustment switch -> full jet
6
switch: roof turret deflector adjustment switch -> spray
7
switch: manual throttle increasement
8
switch: manual throttle decreasement
9
START - switch: permanent roof turret discharge
10
STOP - switch: permanent roof turret discharge
11
switch: ON / shift switch (Press for 3 sec.)
12
switch: OFF (Press for 3 sec.)
In combination with the shift switch (11), the following switches
change there function:
1+11 switch: open foam compound pressure valve for turret line
5+11 switch: reduce to half output
6+11 switch: full output
9+11 START - switch: engage the roof turret
10+11 STOP - switch: disengage the roof turret
N2
display of remote control
U31 remote control
For further information please refer to the separate operation
manual.
2
4
6
8
10
12
N2
7
9
11
1
3
5
U31
CAUTION !
Sight contact with the turret is absolutely essential!
Never point the discharge jet at anybody.
DANGER OF INJURY TO PERSONNEL!
Before activating the turret control please make sure to have
enough operation area available. The turret moves automatically
into the same position like the control handle is pointing to.
ATTENTION !
Operate the roof turret with closed roof hatch only !