background image

User Manual 

 

75 

  

Calibration Kit

 

Industrial Version 

74CK011-170 

 

 

Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260       D-84526 Tittmoning       Germany 
www.rosenberger.com

 

Tel.    : +49 8684 18-0  
 
Email : info@rosenberger.com

 

Page 

 

7 / 15

 

 

D

ie

s

e

s

 D

o

k

u

m

e

n

is

u

rh

e

b

e

rr

e

c

h

tl

ic

h

 g

e

s

c

h

ü

tz

 T

h

is

 d

o

c

u

m

e

n

is

 p

ro

te

c

te

d

 b

y

 c

o

p

y

ri

g

h

 R

o

s

e

n

b

e

rg

e

H

o

c

h

fr

e

q

u

e

n

z

te

c

h

n

ik

 G

m

b

H

 &

 C

o

K

G

 

3.2 Installation of Standard Definitions 

 
The  standard  procedure  to  install  Standard  Definitions  is to  import them  from the  USB stick  onto 
your  VNA.  As  standard  delivery  data  files  for  Vector  Network  Anaylzer  Families  PNA 
(Keysight/Agilent)  and  ZVA  (Rohde&Schwarz)  are  included.  Data  files  for  other  VNA  families  are 
available  on  request.  If  the  specific  data  file  is  not  available,  the  standard  definitions  have  to  be 
installed manually with the provided information from the Standard Definitions Cards. 
 

 

USB-stick

 

The Kit Info Card gives a brief description for the VNAs described above. 
For all others please consult the VNA operating manual. 
 

 

Manual installation

 

The manual installation is a more complex process. Please consult the VNA operating manual. 
Some network analyzers allow a step by step input of the model based standard definitions 
during the VNA calibration without previously loading them. 
 

 

Updating

 

After a re-calibration the standard definitions are optimized on the basis of the actual 
measurements.  
Data files have to be imported like described before. 
For a manual update only the values that have changed have to be modified.  
 

3.4 Standard Definitions file nomenclature 

 
The file  name  includes the  calibration  kit  type,  the  serial  number,  the type  of  standard  definitions 
and the date of calibration. The file extension defines the VNA types the file can be used on. For 
further Information see the Application Note AN001. 
 
KitType 

(SN)

_

StdDef

_

CalDate

.

Ext 

 

  KitType 

74CK011-170 or customized type 

 

 

(SN) 

Serial number (5 character) enclosed by brackets 

 

 

StdDef 

‘mb’ stands for model based and ‘db’ for data based, refer to 3.1 

 

 

CalDate 

Date of kit calibration, these standard definition relate to 

 

 

Ext   

e.g.  

 

‘ckt’   file can be used on Keysight/Agilent VNAs 

 

 

 

PNA family and compatible ones 

 

‘calkit’  file can be used on Rohde&Schwarz VNAs 

 

ZVA, ZVB, ZVBT, ZNB families and compatible ones 

 

Example file name: 
 

74CK011-170 (BH003)_mb_2020-05-30.calkit 

Summary of Contents for 74CK011-170

Page 1: ...hnik GmbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 15 Dieses Dokument ist urheberrechtlich gesch tzt This document is protec...

Page 2: ...4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installation of Standard Defi...

Page 3: ...his calibration kit allow you to perform one port OSL OSM or two port OSLT TOSM and TRM TMR calibrations from DC up to 6 GHz for measurements of Rosenberger components with F 75 connectors Components...

Page 4: ...a 74K12L 001S3 1 Short circuit plug 74S12S 001S3 1 Short circuit jacka 74K12S 001S3 1 Calibration load plug 74S150 C11S3 1 Calibration load jacka 74K150 C11S3 1 Calibration Adaptor plug plug 74S121 S2...

Page 5: ...PNA Keysight Agilent and ZVA Rohde Schwarz Calibration Certificate as PDF file Standard Definitions Cards Printed Standard Definitions that can be used on nearly all Vector Network Analyzers Kit Info...

Page 6: ...ure range for which the specifications are valid is defined in the specific data sheets 2 2 Electrical and mechanical Specifications Electrical and mechanical specifications are defined for all calibr...

Page 7: ...a more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously l...

Page 8: ...thmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the dynamic range Sweep time Connect test port ca...

Page 9: ...ilable In cases when the two VNA test ports have different connector systems installed e g RPC N 75 and F 75 UOSM can handle this situation A second calibration kit is needed Calibration Procedure Ada...

Page 10: ...cal Rosenberger sales office Please use the Service Form at the end of this manual if there are any known problems with your calibration kit 5 4 Extent of Rosenberger Re Calibration Services Every cal...

Page 11: ...s will usually also have raised edges around them and will make less than perfect contact further to this raised edges on mating interfaces will make dents in other connectors to which they are mated...

Page 12: ...olvents directly on to the connector surfaces or use contaminated solvents Use the low pressure compressed air once again to remove any remaining small particles and to dry the surfaces of the connect...

Page 13: ...grity non destructive mating and electrical performance of the connector The mechanical gauging of coaxial connectors will detect and prevent the following problems Inner conductor protrusion This may...

Page 14: ...ways wear a grounded wrist strap and work on a grounded conductive table mat 2 Visually inspect the connectors 3 If necessary clean the connectors Refer to 4 1 Connector Care 4 Check connector gage ac...

Page 15: ...onnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connecting nut C...

Reviews: