background image

8-port Gigabit Desktop Switch 

RC-410LX                                                                   User Manual 

 

FCC STATEMENT 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to pro-vide reasonable protection against harmful interference in a residential installation. This equipment 

generates, uses and can radiate radio frequency energy and, if not in-stalled and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, 

the user is encouraged to try to correct the interference by one or more of the following measures: 

• Reorient or relocate the receiving antenna. 

• Increase the separation between the equipment and receiver. 

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

• Consult the dealer or an experienced radio/ TV technician for help.   

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 

 

1) This device may not cause harmful interference. 

2) This device must accept any interference received, including interference that may cause undesired operation. 

 

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the 

equipment. 

 

CE Mark Warning 

This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to 
take adequate measures. 

 

 

- 2 -

Summary of Contents for RC-410LX

Page 1: ...8 port Gigabit Desktop Switch RC 410LX User Manual ...

Page 2: ... is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of...

Page 3: ...demarks of their respective holders No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from ROSEWILL INC Copyright 2009 ROSEWILL INC All rights reserved http www rosewill com Special Icons that needs your attention NOTE This mark indicates that there is a note of interest or ...

Page 4: ...ontains the above items If any of the listed items are damaged or missing please contact with your distributor Safety Notices Cautions Do not use this product near water for example in a wet basement or near a swimming pool Avoid using this product during an electrical storm There may be a remote risk of electric shock from lightning Convention The Switch or RC 410LX mentioned in this User Guide s...

Page 5: ...put The RC 410LX switch is compatible with all 10Mbps 100Mbps and 1000Mbps Ethernet devices which can protect your existing network investments while provide you a straightforward migration path to faster Gigabit speed The RC 410LX switch is very easy to manage since it is plug and play and no configuration is needed In addition the auto MDI MDI X cable detection on all ports eliminates the demand...

Page 6: ...upporting Auto MDI MDIX Supports IEEE802 3x flow control for Full duplex Mode and backpressure for Half duplex Mode Non blocking switching architecture that forwards and filters packets at full wire speed for maximum throughput 4K entry MAC address table of the RC 410LX with auto learning and auto aging Supports for Jumbo frames of up to 9KB LED indicators for monitoring power link speed and activ...

Page 7: ...used with DC power supply Powering on the Switch it will automatically initialize and its LED indicators will respond as follows Name Time Status Indication Power All the time On Power on 1st 3rd second Off N A On yellow No device connected to the corresponding port 4th 6th second On green There is a 10 100 1000Mbps device connected to the corresponding port Off No device connected to the correspo...

Page 8: ...port On yellow There is a 10 100Mbps device connected to the corresponding port Flashing yellow Data transmitting or receiving on corresponding port 10 100Mbps Off No 10 100Mbps device connected to the corresponding port Note The LEDs description above explains the device s working status after initialization Rear Panel Figure 3 2 RC 410LX Switch Rear Panel The following parts are located on the r...

Page 9: ...TP maximum 100m Network Media Cable 1000Base TX UTP category 5 cable maximum 100m EIA TIA 568 100Ω STP maximum 100m Number of Ports 8 x 10 100 1000M RJ45 ports LED indicators Power 10 100 1000Mbps Link Act Transfer Method Store and Forward MAC Address Learning Automatically learning automatically aging 10Base T 14880pps Port 100Base Tx 148800pps Port Frame Filter Rate 1000Base T 1488000pps Port 10...

Page 10: ...evice is connected to the corresponding port Check to see if the cable connectors are firmly plugged into the Switch and the device and verify the connected device is turned on and working well Make sure the cable is not longer than 100 meters 328feet Thank you for purchasing a quality Rosewill Product Please register your product at www rosewill com for complete warranty information and future su...

Reviews: