removing or replacing the Remote.    Some of the plastic edges are a little sharp.     

The Remote is often attached to the Main unit when storing, when transporting, or when patch cables are being tested.   

The Remote is removed from the Main unit when an installed (in wall, ceiling, etc.) cable is being tested.    

 

Testing Patch Cables 

 

 

“Patch” cables have both ends accessible at the same location.    Usually, but not always, these cables are less than 25ft 

in length, and are not installed in a wall or ceiling.    Since both ends are accessible, one end can be plugged into the 5 in 

1 Main unit, and one end into the Remote unit.    It is not necessary to remove the Remote unit from its docked position 

on the Main unit.     

 

Testing Installed Cables 

 

To test cables installed in ceilings or walls, or in applications that prevent the ends from being in the same location, the 

Remote can be detached from the Main unit.    Once detached, the Remote can be attached to one end a cable, and the 

Main unit attached to the other end of the cable.    These ends are often in different rooms and on different floors of a 

building.   

 

Performing The Test 

 

Once the Remote and Main unit are attached to the ends of the subject cable, as described in 6.3 and 6.4, testing may 

begin, simply press and release the Test Button on the Main unit, observe the LED indicators, and note the beeping sound 

that comes from the Main unit.     

 

Interpreting the Results

 

Power LED: The Power LED should light whenever the Test Button is pressed and released.    It will stay in for a minimum 

of 5 seconds, or for however long the Test Button is pressed.    If the power LED does not light, replace the battery.   

    Low Battery LED: The low battery LED should not light.    If it does, replace the battery.     

    No connection LED/Single Beep: If the Remote is not connected to the Main unit with a cable, or the     

    cable has no intact conductors, the No Connection LED with light and the Beeper will sound once.     

 

Connected LED/Lo-Hi Beep/Numbered LEDs: If the Connected LED lights and the Beeper emits a Lo-Hi beep, 

examine the numbered LED (i.e. LEDs numbered 1 to 8 and the S/G LED) 

Note:  

When testing on RJ-45 UTP cable, the S/G LED must not light.    When testing on RJ-45 UTP cable, the S/G must light.     

The 5 in 1 is intended to test complete cables.    It may not find faults in cables that are intentionally incomplete.    For 

example, the standard EIA/TIA 568 RJ-45 terminated Ethernet cable is expected to contain 8 conductors.    If only 4 

conductors are used between the RJ-45 connectors, the 5 in 1 may not properly identify the faults.     

RJ-11 cables may have 2 connections, 4 connections or as many as 6 connections. For 2 connection cables, LED 3 and 4 

must light.    For 4 connection cables, LED 2, 3, 4 and 5 must light.    For 6 connection cables, LED 1, 2, 3, 4, 5 and 6 must 

light.    The Numbered LEDs DO NOT indicate that a GOOD connection exists, only that a connection exists.  If the Short 

or Cross LEDs are lit, there is a fault in the cable.     

Summary of Contents for RTK-T05

Page 1: ...5 in 1 Cable Tester RTK T05 User Manual...

Page 2: ...esult in damage to the tester or injury to the user Repairs and maintenance must only be carried out by qualified service personnel or qualified electricians technicians who know the dangers of and th...

Page 3: ...ter Do not use the tester if there is evidence of chemical leakage from the battery 3 PRODUCT FEATURES Test 5 types of cables Simple one button tester Ergonomic portable handheld design Tests installe...

Page 4: ...eased 6 status LEDs indicate the condition of the cable being tested as well as informing the user that Power is turned on and that the battery is good or bad 8 additional connection LEDs light to ind...

Page 5: ...und that comes from the Main unit Interpreting the Results Power LED The Power LED should light whenever the Test Button is pressed and released It will stay in for a minimum of 5 seconds or for howev...

Page 6: ...ormation that the uninitiated may find helpful Cable Damage When a cable tests badly either the wire or the connectors or both may be at fault If the cable has been installed and working then it s lik...

Page 7: ...d cable But it may work just fine as crossover cable The 5 in 1 says my cable is good but it does not work on my LAN Many cable testers like the 5 in 1 only perform continuity style tests open short c...

Page 8: ...used simpler approach is to replace the good cable with a reversed cable making the polarity come out correctly It is also worth knowing that some female female couplers reverse the polarity of the p...

Reviews: