background image

replaced.  To  restart  the  hour  counter  (RESET),  hold  the  button  A  pressed  down  for  about  1”  (while  the  pilot  lamp
S  is  on).  Button  B:  drives  the  motor  in  first  speed  (the  corresponding  pilot  lamp  comes  on);  when  holding  it  down
for  about  1”,  the  motor  cuts  out;  when  pressing  the  button  a  second  time  (while  the  pilot  lamp  is  on)  ,  the  TIMER
is  activated  and  thus  the  motor  stops  after  5’  (the  pilot  lamp  flashes).

 

Button  C:  drives  the  motor  in  second  speed

(the  corresponding  pilot  lamp  comes  on);  when  pressing  the  button  a  second  time  (while  the  pilot  lamp  is  on)  ,
the  TIMER  is  activated  and  thus  the  motor  stops  after  5’  (the  pilot  lamp  flashes).  Button  D:  drives  the  motor  in
third speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp
is  on)  ,  the  TIMER  is  activated  and  thus  the  motor  stops  after  5’  (the  pilot  lamp  flashes).  Button  E:  drives  the
motor  in  fourth  speed  (the  corresponding  pilot  lamp  comes  on);  when  pressing  the  button  a  second  time  (while
the  pilot  lamp  is  on)  ,  the  TIMER  is  activated  and  thus  the  motor  stops  after  5’  (the  pilot  lamp  flashes).

Pay  special  attention  to  the 

grease  filters;

  to  remove  the  filter:  push  inward  on  the  clamp  at  the  handle  and

pull  the  filter  downward.    Wash  out  the  filter  using  a  neutral  soap.  if  the  model  purchased  has  the  controls  shown
in Figure 13: see the paragraph “Controls shown in Fig. 13” (“Filter Alarm”). If the model purchased has the controls
shown  in  Figure  11/12:  the  grease  filter  must  be  cleaned  periodically:  exactly  how  often  depends  on  use  (at  least
once  every  other  month).    If  the  model  purchased  has  the  controls  shown  in  Figure  14:  the  grease  filters  must
be  cleaned  approximately  once  every  30  hours  of  operation  (when  the  light  button  lamp  comes  on)  -  Fig.  14S).
Once  the  cleaned  filters  are  reinstalled,  to  reset  the  counter  hold  the  light  button  pressed  down  for  about  1”
(Fig.14A)  while  the  corresponding  pilot  lamp  (S)  is  on.  For  further  information,  see  the  Controls  in  Fig.14  in  the
paragraph  entitled  “Operation”.

Charcoal  filter/s

:  if  using  the  hood  in  the  filtering  hood,  the  charcoal  filter  must  be  replaced  periodically.  To

remove  the  charcoal  filters,  proceed  as  follows,  depending  on  the  model  purchased:
-  if  the  hood  features  round  charcoal  filters  (Fig.  15),  remove  the  charcoal  filter  by  turning  clockwise.
-  if  the  hood  features  a  panel  type  charcoal  filter  (Fig.  10),  remove  the  charcoal  filter  by  first  of  all  removing  the
two  filter  retainers  M.
If the model purchased has the controls shown in Figure 13, see the paragraph “Controls shown in Fig. 13” (“Filter
Alarm”).  If  the  model  purchased  has  the  controls  shown  in  Figure  11/12,  the  charcoal    filters  must  be  replaced
according to use: on the average once every 6 months. If the model purchased has the controls shown in Figure14,
the  charcoal  filters  must  be  replaced  each  time  the  light  button  (Fig.14S)  lamp  flashes  (i.e.  every  120  hours  of
operation).

Lighting

:

-  To  gain  access  to  the 

bulbs

,  remove  the  grease  filters  as  described  above  and  remove  the  bulbs.  Replace  only

with 

CANDLE HALOGEN LAMP

 - Ø 35mm,  E14–220-240 Vac, 28W  or  

INCANDESCENT LAMP

-E14–220-240 Vac,

40W
-  If  the 

halogen  lamps

  shown  in  Fig.  16  need  changing,  slacken  the  ring  nut  in  an  anticlockwise  direction  and

remove the bulb itself. Replace with the same type of lamp. CAUTION: Do not handle glass bulb with bare hands.
-  To  change  the 

halogen  lamps

  shown  in  Fig.  17  open  the  cover  levering  from  the  proper  slots.  Replace  with

the  same  type  of  lamp.  CAUTION:  Do  not  handle  glass  bulb  with  bare  hands.

The motor used in this hood features a safety device (thermal cutout) that responds to temperature changes

For accidental reasons or due to installation faults, this device could engage and automatically shut off the
motor, thereby preventing serious damage to the equipment. In such cases, after allowing the motor to cool
down,  the  hood  can  be  switched  on  again;  the  cause  of  the  fault  will  nonetheless  have  to  be  remedied,
ensuring installation has been correctly made and that all the instructions in the Information sheet have been
complied with.

Summary of Contents for RDR 61/2

Page 1: ... USE MONTAGE UND GEBRAUCHSANWEISUNG INSTRUCTIONS POUR L INSTALLATION ET L UTILISATION ISTRUZIONI PER L INSTALLAZIONE E L USO INSTRUCCIONES PARA INSTALACIÓN Y USO AANWIJZING VOOR GEBRUIK EN INSTALLATIE BYCNHERWBB GJ GJKMPJDFYB DSNZ RJQ ...

Page 2: ...ten the air baffle to the lower flue as shown in Figure 8 using the 2 screws Take 2 assembled flues and place these on the upper surface of the hood Raise the upper flue as far as the ceiling and secure it to the bracket using the 2 screws Fig 7 Also remember that charcoal filters must be used in the case of the filtering version check to see whether such filters are already fitted if necessary pr...

Page 3: ...r information see the Controls in Fig 14 in the paragraph entitled Operation Charcoal filter s if using the hood in the filtering hood the charcoal filter must be replaced periodically To remove the charcoal filters proceed as follows depending on the model purchased if the hood features round charcoal filters Fig 15 remove the charcoal filter by turning clockwise if the hood features a panel type...

Page 4: ...lschelle befestigen Schlauch und Schelle werden nicht mitgeliefert Schließen Sie die Haube mittels Stromkabel an die Stromversorgung an Legen Sie die beiden vormontierten Rohre auf den vorderen Teil der Haube Heben Sie das obere Rohr bis zur Decke an und bestigen Sie es mittels 2 Schrauben an der Halterung Abb 7 Umluftversion Schließen Sie die Haube mittels Stromkabel an die Stromversorgung an Bef...

Page 5: ...Abhängigkeit vom Gebrauch mindestens jedoch alle zwei Monate zu reinigen Hat das von Ihnen erworbene Modell die in Abb 14 dargestellten Bedienung die Fettfilter sind jeweils nach etwa 30 Betriebsstunden zu reinigen wenn die Anzeige der Lichttaste aufleuchtet Abb 14S Sind die Filter wieder eingesetzt zur Wiederaufnahme der Stundenzählung circa 1 lang die Taste Licht Abb 14A gedrückt halten während ...

Page 6: ...ne sont pas fournis Effectuez le branchement électrique de la hotte à l aide du câble d alimentation Prendre les 2 tuyaux ensemble et les poser sur la partie supérieure de la hotte Soulevez le tuyau supérieur jusqu au plafond et fixez le au support à l aide des 2 vis Fig 7 Versione recyclage effectuez le branchement électrique de la hotte à l aide du câble d alimentation Fixez le déflecteur d air ...

Page 7: ...des représentées sur la Figure 14 les filtres à graisse doivent être nettoyés environ toutes les 30 heures de fonctionnement lorsque le témoin de la touche éclairage s allume Fig 14S Une fois les filtres propres remontés pour faire repartir le comptage maintenir la pression pendant environ 1 sur la touche éclairage Fig 14A tandis que le témoin lumineux correspondant S est allumé Pour toute informa...

Page 8: ...1 2 A 3 4 ...

Page 9: ...7 8 9 10 M 6 50mm W 5 B min 65 cm A C ...

Page 10: ...15 16 17 13 11 12 A B C D E A C B 14 A B D E C S ...

Page 11: ...04306513 7 ...

Page 12: ...chung mit einer Kontaktöffnung von minde stens3mmversehenist somüssendieentsprechen den Trennvorrichtungen bei der festen Installation YRUJHVHKHQ ZHUGHQ DV HUlW VR DXIVWHOOHQ GDVV GHU 6WHFNHU XJlQJOLFK LVW IDOOV KU HUlW PLW HLQHP Netzkabel mit Stecker ausgestattet ist Vor jeder Reinigungs oder Wartungsarbeit muss GDV HUlW YRP 6WURPQHW JHWUHQQW ZHUGHQ GEBRAUCH In der unmittelbaren Nähe des Geräts d...

Page 13: ...LO LV especially dangerous in this respect Do not use uncovered electric grates 7R DYRLG SRVVLEOH ULVNV RI UH DOZD V FRPSO ZLWK the indicated instructions when cleaning anti grease OWHUV DQG ZKHQ UHPRYLQJ JUHDVH GHSRVLWV IURP WKH appliance This appliance is not intended for use by persons LQFOXGLQJ FKLOGUHQ ZLWK UHGXFHG SK VLFDO VHQVRU or mental capabilities or lack of experience and knowledge unl...

Page 14: ...OOpH DX GHVVXV GH FXLVLQLqUHV j XVDJH GRPHVWLTXH dispositifs de cuisson et appareils similaires ENTRETIEN 8Q HQWUHWLHQ VRLJQp HVW XQH JDUDQWLH GH ERQ IRQ ctionnement et de bon rendement de votre appareil dans le temps pOLPLQDWLRQ G pYHQWXHOV GpS WV GH JUDLVVH VXU O DS SDUHLO GRLW rWUH HIIHFWXpH HQ IRQFWLRQ GH O XWLOLVDWLRQ GH FH GHUQLHU DX PRLQV WRXV OHV PRLV O IDXW pYLWHU d utiliser des produits ...