Control Reliable Double Valves
with Dynamic Monitoring & Memory
This valve is not designed for controlling clutch/brake mechanisms on mechanical power presses,
see DM2
®
series D for mechanical power press applications.
Explosion proof solenoid pilot available, for more information consult ROSS.
DM
2®
Series C
Air Dump / Release
Simplified Schematic
1
3
2
Basic Size 2, 4, 8, 12 and 30
Dynamic Monitoring With Complete Memory:
Memory, monitoring, and air flow control functions are
simply integrated into two identical valve elements. Valves lock-out due to asynchronous movement of valve
elements during actuation or de-actuation, resulting in a residual outlet pressure of less than 1% of supply.
An Action is Required for Reset
– cannot be reset by removing and re-applying supply pressure. Reset
can only be accomplished by the optional integrated electrical (solenoid) reset.
Basic 3/2 Normally Closed Valve Function:
Dirt tolerant, wear compensating poppet design for quick
response and high flow capacity. PTFE back-up rings on pistons to enhance valve endurance – operates
with or without inline lubrication.
Status Indicator:
Includes a pressure switch with both normally open (NO) and normally closed (NC)
contacts to provide status feedback to the control system indicating whether the valve is in the lockout or
ready-to-run condition.
Silencers:
All models include high flow, clog resistant silencers.
Mounting:
Base mounted – with BSPP or NPT pipe threads. Inlet and outlet ports on both sides provide
for flexible piping (plugs for unused ports included). Captive valve-to-base mounting screws.
Basic Size 12 and 30
Intermediate Pilots:
Increases pilot air flow for fast valve response, making it possible to use the same size
solenoids as valve sizes 2, 4 & 8, thereby reducing electrical power requirements for these larger valves.
DM2C
N
A
4 2 A
2
1
Basic Size
2
2
4
4
8
5
12
6
30
8
Solenoid
Reset Type
Thread
BSPP
D
NPT
N
Status Indicator
Yes
1
No
X
Base Port Size
2 1/4 inlet – 1/4 outlet
0
3/8 inlet – 3/8 outlet
1
4 1/2 inlet – 1/2 outlet
2
8 3/4 inlet – 3/4 outlet
1 inlet – 1 outlet
4
5
12 1 inlet – 1 outlet
6
30 1
1/2
inlet - 2 outlet
8
HOW TO ORDER
(Choose your options (in red) to configure your valve model number.)
Voltage
*
24 volts DC
A
110 volts AC, 50 Hz
120 volts AC, 50/60 Hz
B
*
For other voltages consult ROSS.
Connection Type
EN 175301-803 Form A
*
(connector not included)
Blank
M12 (connector included)
005
*
See options for connectors
or wiring kits.
ISO 13849-1:2006
Category 4 PL e
applications
HSM 06008
Sicherheit seprüft
tested safety
√
Construction:
Dual poppet.
Mounting Type:
Base mounted.
Pilot Solenoids:
According to VDE 0580. Enclosure rating according to
DIN 400 50 IP 65. Three solenoids, rated for continuous duty.
Standard Voltages/Pilot Solenoids Power Consumption
(each solenoid):
Basic Size 2, 4, 12 & 30:
Primary and reset solenoids:
24 volts DC; 110 volts AC, 50 Hz; 120 volts AC, 50/60 Hz.
5.8 watts nominal on AC and DC; 6.5 watts maximum on AC and DC.
Basic Size 8:
Primary solenoids:
15 watts on DC; 36 VA inrush and 24.6 VA holding on AC.
Reset solenoid:
6.0 watts on DC; 15.8 VA inrush and 10.4 VA holding on AC.
Enclosure Rating:
IP65, IEC 60529.
Electrical Connection:
EN 175301-803 Form A, or M12.
Ambient Temperature:
15° to 122°F (-10° to 50°C).
Media Temperature:
40° to 175°F
(4° to 80°C).
Flow Media:
Filtered, lubricated or unlubricated (mineral oils according
to DIN 51519, viscosity classes 32-46).
Inlet Pressure:
Basic Size 2:
45 to 150 psig (3.1 to 10.3 bar).
Basic Size 4, 8, 12, 30:
30 to 120 psig (2.1 to 8.3 bar).
Pressure Switch (Status Indicator) Rating:
Contacts - 5 amps at 250
volts AC, or 5 amps at 30 volts DC.
Monitoring:
Dynamically, cyclically, internally during each actuating and
de-actuating movement. Monitoring function has memory and requires
an overt act to reset unit after lockout.
Mounting Orientation:
Preferably horizontally (valve on top of base) or
vertically with pilot solenoids on top.
Functional Safety Data:
Category 4 PL e; B10d: 20,000,000; PFHd:
7.71x10
-9
; MTTFd: 301.9 (n
op
: 662400).
Certifications
: CE Marked for applicable directives, DGUV Test, CSA/UL,
TSSA for appropriately tested valves.
Vibration/Impact Resistance:
Tested to BS EN 60068-2-27.
STANDARD SPECIFICATIONS
(for valves on this page)
:
F
F3
REVISION LEVEL
Size 4, 8, 12, 30
A
Size 2
B
(Basic Size 2
DGUV, CE
Certifications
pending)
Basic
Size
Inlet
Port Size
C
V
Weight
lb (Kg)
1-2
2-3
2
1/4
1.67
2.61
5.3 (2.4)
2
3/8
2.17
2.61
5.3 (2.4)
4
1/2
3
10
5.9 (2.6)
8
3/4
4.2
13
8.4 (3.7)
8
1
4.4
13
8.4 (3.7)
12
1
8.5
20
15.3 (3.7)
30
1
1/2
22
64
34.7 (15.1)
#
Valve and base assembly with status indicator.