DETOUR User Guide (v3.0)

Installation • 11

Installation

This chapter provides information on the DETOUR hardware components and instructions for the basic physical 
installation of the DETOUR in your system. 

Static Discharge

Throughout this chapter, please heed the following cautionary note: 

Power Adapter and Supply

DETOUR may be powered from its USB connector

1

, or an external 5V power supply. However, DETOUR 

operation is dependent on the connected power source (or absence thereof) as follows:

• OUT 1 and failsafe operation is available when either power source is connected. DETOUR functions as a 

reclocker with relay bypass.

• OUT 2, 3 and 4 are available for use when the external 5V power source is connected. DETOUR functions as 

1x4 Reclocking DA with relay bypass.

• When no power is available to DETOUR from either USB or external sources, the relay bypass allows the 

BYPASS IN signal to connect to OUT 1. 

Connecting to a 5V PSU

Connect the PS-9000 power adapter to the power supply connector. The PS-9000 provides reg5V DC (5%) 
@ up to 2A. The DC power cord has a locking connector that securely fastens into the power supply DC jack on the 
DETOUR. The DETOUR has a standard miniature power jack (center pin positive). Refer to the document 

Important Regulatory and Safety Notices to Service Personnel

” that accompanied your module for details.

Using the USB as the Power Source

Connect the DETOUR to a USB Power Source via the mini-B connector on the DETOUR chassis. 

Ensure that the USB Power Source supports the power consumption requirements listed in 

Table 7.5

 on page 31.

ESD Susceptibility

 — Static discharge can cause serious damage to sensitive semiconductor 

devices. Avoid handling circuit boards in high static environments such as carpeted areas and when 
synthetic fiber clothing is worn. Always exercise proper grounding precautions when working on circuit 
boards and related equipment.

1. OUT 2, 3, and 4 are not available when operating on USB power only.

Summary of Contents for 9201DR-104-03

Page 1: ...DETOUR User Guide...

Page 2: ...eople that make things happen At Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics...

Page 3: ...errors or inaccuracies that may appear in this manual Statement of Compliance This product has been determined to be compliant with the applicable standards regulations and directives for the countrie...

Page 4: ...tion on the last page of this manual All GearLite products are covered by a generous 3 year warranty and will be repaired without charge for materials or labor within this period See the Warranty and...

Page 5: ...O Box 880 Ogdensburg New York USA 13669 0880 General Business Office 1 613 652 4886 Fax 1 613 652 4425 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail Technical Support t...

Page 6: ......

Page 7: ...element such as a dialog box menu item or button For example In the Edit dialog click Apply User Entered Text Courier text is used to identify text that a user must enter For example In the Language...

Page 8: ...pport person who is on call does not answer this line immediately a voice message can be left and the call will be returned shortly This team of highly trained staff is available to react to any probl...

Page 9: ...the alarm state detection method This is particularly useful when coupled with an Ultrix router If Ultrix loses power then the USB connection between Ultrix and DETOUR can trigger the bypass state Fo...

Page 10: ...y acts immediately on the first two bypass error condition state changes e g error error cleared then applies a user configurable timer to prevent multiple state change triggers Figure 2 2 Figure 2 2...

Page 11: ...l to connect to OUT 1 Connecting to a 5V PSU Connect the PS 9000 power adapter to the power supply connector The PS 9000 provides regulated 5V DC 5 up to 2A The DC power cord has a locking connector t...

Page 12: ...elay is as follows If the DETOUR loses power the video still passes through When the DETOUR boots the relay will be left in Bypass mode until the DETOUR can generate a valid output Once the DETOUR is...

Page 13: ...is a general purpose output that provides contact closure alarm state monitoring Under normal operation the Center pin 2 is connected to Pin1 normally closed An alarm condition connects pin 2 to pin...

Page 14: ...not locked to a valid SDI signal 5V 2A Green When this LED is continually lit green the DETOUR is receiving 5VDC on the POWER DC port of its chassis Off When this LED is unlit the POWER port is not re...

Page 15: ...bnet Mask and Gateway for your DETOUR To assign the initial static IP address for DETOUR 1 Launch DashBoard 2 From the DashBoard client main toolbar select File Show Walkabout The DashBoard window dis...

Page 16: ...ext fields provided enter the display name for the DETOUR and port of the module you wish to add Click Detect Frame Information to automatically retrieve the connection details 8 Click Finish The DETO...

Page 17: ...name displays in the Tree View and the Device Name in the Product Status tab for the module 3 Click Apply to save the new settings Configuring the Bypass Relay DETOUR includes a bypass relay between...

Page 18: ...configure the equalizer 1 From the Device View select the Setup tab 2 Select the EQ Enable box The box displays a check mark To bypass the equalizer 1 From the Device View select the Setup tab 2 Clea...

Page 19: ...tion tab An alarm condition will also trigger the general purpose interface GPI state Enabling the LOS Alarm in DashBoard When enabled this feature will indicate an alarm condition red in the correspo...

Page 20: ...1 From the Device View select the Setup tab 2 Click Factory Settings Restore to display the Confirm dialog 3 Perform one of the following steps Click Yes to load the factory defaults or Click No to ca...

Page 21: ...or messages Table 5 2 outlines the read only information displayed in the Hardware tab Table 5 1 Signal Tab Parameters Description Signal Presence Present Green A valid input signal is connected to th...

Page 22: ...is not connected to the USB port power is supplied via the POWER port only Table 5 3 Network Status Tab Item Parameters Description IP Address Indicates the IP address assigned to this DETOUR Subnet M...

Page 23: ...YPASS IN HD BNC is used Cleared Disables this feature Relay Bypass on Lock Error Selected DETOUR automatically switches to Bypass mode when the SDI reclocker loses lock or the reclocker rate is fixed...

Page 24: ...reports when an input signal is not detected Cleared Disables the alarm The input signal is not monitored Alarm on External Power Loss Selected The External Power field in the Hardware tab reports whe...

Page 25: ...DETOUR User Guide v3 0 DashBoard Menus 25 Apply Updates the Network tab fields Cancel Ignores any unsaved changes made to the Network tab fields Table 5 6 Network Tab Item Parameters Description...

Page 26: ...26 DashBoard Menus DETOUR User Guide v3 0...

Page 27: ...ETOUR User Manual provides all pertinent information for the safe installation and operation of your GearLite Product Ross Video policy dictates that all repairs to the GearLite DETOUR are to be condu...

Page 28: ...28 Warranty and Repair DETOUR User Guide v3 0...

Page 29: ...2 1 Connector Type HD BNC Equalization SDI Input 270Mbps 450m 1 485Gbps 250m 2 97Gbps 200m 5 94Gbps 90m 11 88Gbps 70m Bypass Input While DETOUR does not provide equalization on this input there is no...

Page 30: ...DI Outputs 270Mbps 400 800ps 1 485Gbps 2 97Gbps 135ps 5 94Gbps 80ps 11 88Gbps 45ps Bypass Output 270Mbps 400 800ps 1 485Gbps 2 97Gbps 175ps 5 94Gbps 80ps 11 88Gbps 65ps Table 7 3 Technical Specificati...

Page 31: ...Technical Specifications Power Item Specifications Required Voltage 5V Current USB 500mA External Supply 600mA Table 7 6 Technical Specifications Dimensions Item Specifications Physical Dimensionsa a...

Page 32: ...32 Technical Specifications DETOUR User Guide v3 0...

Reviews: