2-10
Tools Required for Module Installation
To remove or install the MBus or hyperSPARC module, you will need:
For a SPARCserver 600MP System Board
Phillips screwdriver (size #2)
Flat blade screwdriver
Allen wrench (2.5 mm)
ESD kit P/N 250-1088
For a SPARCstation 10 or SPARCstation 20 Main Logic Board:
Phillips screwdriver (size #1)
Phillips screwdriver (size #2)
Needle-nose pliers
Antistatic mat
Disposable wrist strap
Electrostatic Discharge Precautions
Caution: Circuit board components are vulnerable to damage by electrostatic discharge (ESD). An
electrostatic charge can build up on the human body and then discharge when you touch a board. Such
discharge can be produced by walking across a carpet and touching a board, or by other similar causes.
Before handling any board, make sure you dissipate your body’s charge. Touch a conductive surface of the
chassis or other element connected to common earth ground to discharge the static electricity present in your
body. To minimize risk of ESD damage:
Handle board by edges only
Store board in antistatic bag provided
2.5 Using the Disposable Wrist Strap
The wrist strap is a device that provides grounding for static electricity between your body and the system
unit chassis. Electric current and voltage do not pass through the wrist strap. When needed, attach the wrist
strap to your wrist and to the metal case or the power supply. Parts that require the use of a wrist strap are
packed with one.
Caution: Boards and modules can be damaged by harmful electrical charges of you do not wear a wrist
strap.
Summary of Contents for hyperSPARC
Page 2: ...hyperSPARC Module Installation Guide TM...
Page 9: ...1 4...
Page 21: ...2 12...
Page 55: ...5 10...