background image

IMPORTANT NOTE:

 

 Please read carefully and thoroughly all of the 

CAUTIONS, WARNINGS

 

on the inside back cover.

F3.19

www.rosscontrols.com

Online Version
Rev. 11/14/16

DM

1

 Series E Double Valves, Manual Lockout L-O-X

®  

Valves with Integrated Filter/Regulator

DM

2® 

Series E Double Valves, Manual Lockout L-O-X

®  

Valves with Integrated Filter/Regulator

NOTE:  Per specifications and regulations, these products are defined as energy isolation devices, NOT AS EMERGENCY STOP DEVICES.

RC Series

Air Entry Packages

 

with DM Series E Double Valves - Control Reliable Energy Isolation

Pre-engineered panel-mounted design with air entry via a filter and regulator “FR”, or filter, regulator 
and lubricator “FRL”.
Includes DM

Series E Double Valve with Monitoring:

a) Self-contained dynamic monitoring system requires no further valve monitoring controls,
b) Ready-to-run:  If an abnormality clears itself upon the removal of electricity to both solenoids, it 
will be ready-to-run again. It does not remember the abnormality & stay in a locked-out state until 
intentionally reset.  Therefore, cumulative abnormalities may go undetected,
c) Status indicator switch for valve condition (ready-to-run) feedback.

Mounting plate included.

Air Entry Combination

Port Size

Model Number

*

Air Entry 

Type

C

V

Dimensions 

inches (mm)

1, 2

3

1-2

2-3

Length

Width

Depth

Cat-4 with DM1 Series E 1/4

1/2

RC304-09

**

FR

1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7) 

Cat-4 with DM1 Series E 3/8

1/2

RC306-09

**

FR

2.2 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)

Cat-4 with DM1 Series E 1/4

1/2

RC304L-09

**

FRL

1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)

Cat-4 with DM1 Series E 3/8

1/2

RC306L-09

**

FRL

2.2 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)

*

 NPT pressure port threads.

**

 Specify voltage when ordering.  Insert voltage code: “

W

” = 24 volts DC; “

Z

” = 110-120 volts AC, 50/60 Hz; e.g., RC304-09

W

M12 connectors available, consult ROSS. 
Standard Air Entry Packages supplied with metal bowl and manual drain.  For automatic drain insert an “

A

” before the dash 

(-) in the model number, e.g., RC304

A

-09.

4

Pre-engineered panel-mounted design with air entry via a filter and regulator “FR”, or filter, regulator 
and lubricator “FRL”.
Includes DM

2® 

Series E Double Valve with Monitoring & Memory:

a) Self-contained dynamic monitoring system requires no further valve monitoring controls,
b) Dynamic memory of abnormal function prevents unintentional reset with removal of air or electricity.
All necessary features for safety applications are included:
a) Electrical reset valve,
b) Status indicator switch for valve condition (ready-to-run) feedback.

Mounting plate included.

Air Entry 

Combination

Port Size

Model

Number

*

Air Entry 

Type

C

V

Dimensions 

inches (mm)

1, 2

3

1-2

2-3

Length

Width

Depth

Cat-4 with DM2

®

 Series E 1/4 1/2

RC404-09

**

FR

1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)

Cat-4 with DM2

®

 Series E 3/8 1/2

RC406-09

**

FR

2.2 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)

Cat-4 with DM2

®

 Series E 1/4 1/2 RC404L-09

**

FRL

1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)

Cat-4 with DM2

®

 Series E 3/8 1/2 RC406L-09

**

FRL

2.2 2.4  13.00 (330.0) 11.00 (279.0) 5.40 (134.7)

*

 NPT pressure port threads.

**

 Specify voltage when ordering.  Insert voltage code: “

W

” = 24 volts DC; “

Z

” = 110-120 volts AC, 50/60 Hz; e.g., RC404-09

W

M12 connectors available, consult ROSS. 
Standard Air Entry Packages supplied with metal bowl and manual drain.  For automatic drain insert an “

A

” before the 

dash (-) in the model number, e.g., RC404

A

-09.

Pressure 

Switch 

not shown

Custom designs available, consult ROSS.

4

Custom designs available, consult ROSS.

F

F3

Summary of Contents for M DM2 C Series

Page 1: ...he model number with a D e g MDM2CDA55A23 STANDARD SPECIFICATIONS for valves on this page Double Valves with Dynamic Monitoring Memory 10 78 273 8 5 73 145 5 5 35 136 0 5 81 147 6 Adjustable Flow Control Inlet Outlet 1 63 41 3 GRAY Equip Ground WHITE N O Status Contact BROWN 24 Volts DC BLUE Common 5 Pin A Code Female Connector BLACK N C Status Contact 1 2 5 4 3 GRAY Reset WHITE Sol 2 BROWN 24 Vol...

Page 2: ... inlet poppet and return piston to hold the element in the fully closed position Inlet air flow on side A into its crossover is restricted and flows through the open inlet poppet on side B through the outlet into the exhaust port and from the exhaust port to atmosphere Residual pressure in the outlet is less than 1 of inlet pressure The return springs are limited in travel and can only return the ...

Page 3: ...ed port must be closed with a pipe plug The inlet and outlet are not threaded Specially designed clamps provide a quick and easy assembly or disassembly of MD3TM modules Two allen head bolts quickly tighten or loosen the clamp using a 5 32 or 4mm hex key The clamp contains a plate carrying two O rings to provide positive sealing between modules Order clamp by part number R A118 105 Combined clamp ...

Page 4: ... 2 4 13 00 330 0 11 00 279 0 5 40 134 7 NPT pressure port threads Specify voltage when ordering Insert voltage code W 24 volts DC Z 110 120 volts AC 50 60 Hz e g RC304 09W M12 connectors available consult ROSS Standard Air Entry Packages supplied with metal bowl and manual drain For automatic drain insert an A before the dash in the model number e g RC304A 09 4 Pre engineered panel mounted design ...

Page 5: ...DC Z 110 120 volts AC 50 60 Hz e g RC408 06W M12 connectors available consult ROSS Standard Air Entry Packages supplied with metal bowl and manual drain For automatic drain insert an A before the dash in the model number e g RC408A 06 M DM2 Series C Double Valves with Integrated Soft Start Manual Lockout L O X Valves with Integrated Filter Regulators Pre engineered panel mountable design with air ...

Page 6: ...values the figures given in this catalog should not be used to compare ROSS valves with those of other makers The CV ratings given here are intended only for use with performance charts published by ROSS The CV ratings are averages for the various flow paths through the valve and are for steady flow conditions Approvals and Certifications ROSSproductsaredesignedtomeetanumberofindustrialstandards i...

Page 7: ...ally leading to valve failure which risks human injury and or damage to property AVOID INTAKE EXHAUST RESTRICTION 8 Do not restrict the air flow in the supply line To do so could reduce the pressure of the supply air below the minimum requirements for the valve and thereby cause erratic action 9 Do not restrict a valve s exhaust port as this can adversely affect its operation Exhaust silencers mus...