F3.19
www.rosscontrols.com
Online Version
Rev. 11/14/16
DM
1
Series E Double Valves, Manual Lockout L-O-X
®
Valves with Integrated Filter/Regulator
DM
2®
Series E Double Valves, Manual Lockout L-O-X
®
Valves with Integrated Filter/Regulator
NOTE: Per specifications and regulations, these products are defined as energy isolation devices, NOT AS EMERGENCY STOP DEVICES.
RC Series
Air Entry Packages
with DM Series E Double Valves - Control Reliable Energy Isolation
Pre-engineered panel-mounted design with air entry via a filter and regulator “FR”, or filter, regulator
and lubricator “FRL”.
Includes DM
1
Series E Double Valve with Monitoring:
a) Self-contained dynamic monitoring system requires no further valve monitoring controls,
b) Ready-to-run: If an abnormality clears itself upon the removal of electricity to both solenoids, it
will be ready-to-run again. It does not remember the abnormality & stay in a locked-out state until
intentionally reset. Therefore, cumulative abnormalities may go undetected,
c) Status indicator switch for valve condition (ready-to-run) feedback.
Mounting plate included.
Air Entry Combination
Port Size
Model Number
*
Air Entry
Type
C
V
Dimensions
inches (mm)
1, 2
3
1-2
2-3
Length
Width
Depth
Cat-4 with DM1 Series E 1/4
1/2
RC304-09
**
FR
1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM1 Series E 3/8
1/2
RC306-09
**
FR
2.2 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM1 Series E 1/4
1/2
RC304L-09
**
FRL
1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM1 Series E 3/8
1/2
RC306L-09
**
FRL
2.2 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
*
NPT pressure port threads.
**
Specify voltage when ordering. Insert voltage code: “
W
” = 24 volts DC; “
Z
” = 110-120 volts AC, 50/60 Hz; e.g., RC304-09
W
.
M12 connectors available, consult ROSS.
Standard Air Entry Packages supplied with metal bowl and manual drain. For automatic drain insert an “
A
” before the dash
(-) in the model number, e.g., RC304
A
-09.
4
Pre-engineered panel-mounted design with air entry via a filter and regulator “FR”, or filter, regulator
and lubricator “FRL”.
Includes DM
2®
Series E Double Valve with Monitoring & Memory:
a) Self-contained dynamic monitoring system requires no further valve monitoring controls,
b) Dynamic memory of abnormal function prevents unintentional reset with removal of air or electricity.
All necessary features for safety applications are included:
a) Electrical reset valve,
b) Status indicator switch for valve condition (ready-to-run) feedback.
Mounting plate included.
Air Entry
Combination
Port Size
Model
Number
*
Air Entry
Type
C
V
Dimensions
inches (mm)
1, 2
3
1-2
2-3
Length
Width
Depth
Cat-4 with DM2
®
Series E 1/4 1/2
RC404-09
**
FR
1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM2
®
Series E 3/8 1/2
RC406-09
**
FR
2.2 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM2
®
Series E 1/4 1/2 RC404L-09
**
FRL
1.3 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
Cat-4 with DM2
®
Series E 3/8 1/2 RC406L-09
**
FRL
2.2 2.4 13.00 (330.0) 11.00 (279.0) 5.40 (134.7)
*
NPT pressure port threads.
**
Specify voltage when ordering. Insert voltage code: “
W
” = 24 volts DC; “
Z
” = 110-120 volts AC, 50/60 Hz; e.g., RC404-09
W
.
M12 connectors available, consult ROSS.
Standard Air Entry Packages supplied with metal bowl and manual drain. For automatic drain insert an “
A
” before the
dash (-) in the model number, e.g., RC404
A
-09.
Pressure
Switch
not shown
Custom designs available, consult ROSS.
4
Custom designs available, consult ROSS.
F
F3