OGX-FR Series User Guide (v1.0)
Maintenance • 31
Maintenance
This chapter summarizes maintenance tasks such as installing a new frame power supply, cleaning the frame air
filter, and replacing the Cooling Fan Module.
Installing a Frame Power Supply
The PS-OGX is a power factor corrected supply, capable of working with all world AC standards (100-240V). Each
supply has an indicator LED on its front panel, and an error detection circuit that monitors the power supply
operation.
The PS-OGX power supply installs on the right or left side of the OGX-FR chassis.
To install the power supply
1. Carefully unpack the power supply from its box, and retain all packing material for future use, if required.
2. Align the power supply into an unused power slot on the side of the frame.
3. Push the power supply in firmly to ensure a tight connection at the rear of the frame.
Fan Filter Maintenance
Routine maintenance of the fan filter installed in the OGX-FR is highly recommended to ensure proper airflow
through the chassis.
Cleaning the Frame Air Filter
The OGX-FR has a single air filter that is used to prevent dust and airborne particulates from contaminating the
frame. This filter should be cleaned at least once a year; but may need to be cleaned more frequently in some
environments.
To remove the air filter from the frame door
1. Locate the four 3/16”screws (#850-091R) on the frame door faceplate. (
)
Figure 8.1 OGX-FR — Screw Locations on Front Panel
2. Using a Phillips screwdriver, remove the four screws that secure the faceplate. Set the screws aside.
3. Ensure that the side door tabs are disengaged from the door.
4. Remove the faceplate by gently pulling it towards you while avoiding the Diagnostic Panel, the
Toggle
button,
and the
STATUS
LED.
5. Gently remove the air filter off the metal protective screen that separates the filter from the fans.