3–4 • User Controls
DEA-8205 User Manual (Iss. 06)
Factory Default Values
Any channel can be set back to factory settings, where the data rate is set to
HD
and the alarm is
enabled on loss of input.
Use the following procedure to reset a channel to factory default values:
1.
Press and hold the
Bootload
button on the card.
2.
Press the rate selection button for the selected channel. The
Signal Status LED
flashes
green and red for approximately 2 seconds to confirm the reset values.
This completes the procedure for resetting a channel to factory default values.
CH A -
OK/ERROR
Green
When lit, this LED indicates that the signal is passing through
Channel A without errors.
Red
When red, this LED indicates the absence of an input signal on
Channel A.
CH A - HD
Green
When lit, this LED indicates the channel is processing an HD
input signal rate (1.485Gbps).
CH A - SD
Green
When lit, this LED indicates the channel is processing an SD
input signal rate (143Mbps, 177Mbps, 270Mbps, 360Mbps, or
540Mbps).
CH B -
OK/ERROR
Green
When lit, this LED indicates that the signal is passing through
Channel A without errors.
Red
When red, this LED indicates the absence of an input signal on
Channel A.
CH B - HD
Green
When lit, this LED indicates the channel is processing an HD
input signal rate (1.485Gbps).
CH B - SD
Green
When lit, this LED indicates the channel is processing an SD
input signal rate (143Mbps, 177Mbps, 270Mbps, 360Mbps, or
540Mbps).
Table 3.1 LEDs on the DEA-8205
LED
Color
Display and Description