PRE-INSTALLATION or SERVICE

1. Before servicing a valve or other pneumatic component, be sure all 

sources of energy are turned off, the entire pneumatic system is shut 

down and exhausted, and all power sources are locked out (ref: OSHA 

1910.147, EN 1037).
2. All ROSS Group Products, including service kits and parts, should be 

installed and/or serviced only by persons having training and experience 

with pneumatic equipment. Because any product can be tampered 

with and/or need servicing after installation, persons responsible for 

the safety of others or the care of equipment must check ROSS Group 

Products on a regular basis and perform all necessary maintenance to 

ensure safe operating conditions.
3. All applicable instructions should be read and complied with before 

using any fluid power system to prevent harm to persons or equipment. 

In addition, overhauled or serviced valves must be functionally tested 

prior to installation and use. If you have any questions, call your nearest 

ROSS Group location.
4. Each ROSS Group Product should be used within its specification 

limits. In addition, use only ROSS Group components to repair ROSS 
Group Products.

WARNINGS:  Failure to follow these instructions can result in    

 

personal injury and/or property damage. 

FILTRATION and LUBRICATION

1. Dirt, scale, moisture, etc., are present in virtually every air system. 

Although some valves are more tolerant of these contaminants than 

others, best performance will be realized if a filter is installed to clean the 

air supply, thus preventing contaminants from interfering with the proper 

performance of the equipment. The ROSS Group recommends a filter 

with a 5-micron rating for normal applications.
2. All standard ROSS Group filters and lubricators with polycarbonate 

plastic bowls are designed for compressed air applications only. Use the 

metal bowl guard, where provided, to minimize danger from high pressure 

fragmentation in the event of bowl failure. Do not expose these products 

to certain fluids, such as alcohol or liquefied petroleum gas, as they can 

cause bowls to rupture, creating a combustible condition and hazardous 

leakage. Immediately replace crazed, cracked, or deteriorated bowls.
3. Only use lubricants which are compatible with materials used in 

the valves and other components in the system. Normally, compatible 

lubricants are petroleum base oils with oxidation inhibitors, an aniline 

point between 180°F (82°C) and 220°F (104°C), and an ISO 32, or 

lighter, viscosity. Avoid oils with phosphate type additives which can harm 

polyurethane components, potentially leading to valve failure which risks 
personal injury, and/or damage to property.

WARNINGS:  Failure to follow these instructions can result in    

 

personal injury and/or property damage. 

AVOID INTAKE/EXHAUST RESTRICTION

1. Do not restrict air flow in the supply line. To do so could reduce the 

pressure of the supply air below minimum requirements for the valve 

and thereby causing erratic action.
2. Do not restrict a valve's exhaust port as this can adversely affect its 

operation. Exhaust silencers must be resistant to clogging and must 

have flow capacities at least as great as the exhaust capacities of the 

valves. Contamination of the silencer can result in reduced flow and 

increased back pressure.

WARNINGS:  Failure to follow these instructions can result in    

 

personal injury and/or property damage. 

SAFETY APPLICATIONS

1. Mechanical Power Presses and other potentially hazardous machinery 

using a pneumatically controlled clutch and brake mechanism must 

use a press control double valve with a monitoring device. A double 

valve without a self-contained monitoring device should be used only in 

conjunction with a control system which assures monitoring of the valve. 

All double valve installations involving hazardous applications should 

incorporate a monitoring system which inhibits further operation of the 

valve and machine in the event of a failure within the valve mechanism.
2. Safety exhaust (dump) valves without a self-contained monitoring 

device should be used only in conjunction with a control system which 

assures monitoring of the valve. All safety exhaust valve installations 

should incorporate a monitoring system which inhibits further operation of 

the valve and machine in the event of a failure within the valve mechanism.
3. Per specifications and regulations, the ROSS L-O-X

®

 and L-O-X

®

 with 

EEZ-ON

®

, N06 and N16 Series operation products are defined as energy 

isolation devices, NOT AS EMERGENCY STOP DEVICES.

WARNINGS:  Failure to follow these instructions can result in    

 

personal injury and/or property damage. 

CAUTIONS And WARNINGS

STANDARD WARRANTY

All products sold by the ROSS Group are warranted for a one-year period [with the exception of Filters, 

Regulators and Lubricators (“FRLs”) which are warranted for a period of seven (7) years] from the date 

of purchase. All products are, during their respective warranty periods, warranted to be free of defects in material and workmanship. The ROSS 

Group’s obligation under this warranty is limited to repair, replacement or refund of the purchase price paid for products which the ROSS Group 

has determined, in its sole discretion, are defective. All warranties become void if a product has been subject to misuse, misapplication, improper 
maintenance, modification or tampering. Products for which warranty protection is sought must be returned to the ROSS Group freight prepaid.
ALL PRODUCTS SOLD BY THE ROSS GROUP ARE WARRANTED FOR A ONE-YEAR PERIOD [WITH THE EXCEPTION OF FILTERS, REGULATORS 
AND LUBRICATORS (“FRLS”) WHICH ARE WARRANTED FOR A PERIOD OF SEVEN (7) YEARS] FROM THE DATE OF PURCHASE. ALL PRODUCTS 
ARE, DURING THEIR RESPECTIVE WARRANTY PERIODS, WARRANTED TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP. THE 
ROSS GROUP’S OBLIGATION UNDER THIS WARRANTY IS LIMITED TO REPAIR, REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID 
FOR PRODUCTS WHICH THE ROSS GROUP HAS DETERMINED, IN ITS SOLE DISCRETION, ARE DEFECTIVE. ALL WARRANTIES BECOME 
VOID IF A PRODUCT HAS BEEN SUBJECT TO MISUSE, MISAPPLICATION, IMPROPER MAINTENANCE, MODIFICATION OR TAMPERING. 
PRODUCTS FOR WHICH WARRANTY PROTECTION IS SOUGHT MUST BE RETURNED TO THE ROSS GROUP FREIGHT PREPAID.

ROSS

 

CONTROLS USA

 

Tel: 1-248-764-1800 

www.rosscontrols.com

ROSS

 EUROPA GmbH 

Germany

 

Tel: 49-6103-7597-0 

www.rosseuropa.com

ROSS

 ASIA K.K.

 

Japan

 

Tel: 81-42-778-7251 

www.rossasia.co.jp

ROSS

 UK Ltd.

 

UK

 

Tel: 44-1543-671495 

www.rossuk.co.uk

ROSS

 SOUTH AMERICA Ltda. 

Brazil

 

Tel: 55-11-4335-2200 

email: vendas@rosscontrols.com

ROSS

 CONTROLS INDIA Pvt. Ltd. 

India

 

Tel: 91-44-2624-9040 

email: ross.chennai@rosscontrols.com

ROSS

 CONTROLS (CHINA) Ltd.

 

China 

Tel: 86-21-6915-7961 

www.rosscontrolschina.com

ROSS

 

FRANCE S.A.S.

 

France 

Tel: 33-1-49-45-65-65 

www.rossfrance.com

ROSS

 

CANADA  

 

Canada   

Tel: 1-416-251-7677 (416-251-ROSS) 

www.rosscanada.com 

(6077170 CANADA INC. A

n

 

I

ndependent

 R

epResentatIve

)

ROSS OPERATING VALVE, ROSS CONTROLS

®

, ROSS DECCO

®

, and Automatic Valve Industrial, collectively the “ROSS Group".

Reviews: