12
ADJUSTMENTS
Press and release the ADJUSTMENTS button, with intervals shorter than 1 sec. according to the desired program.
1x
- BRAKE
ENC (with encoder)
Ñ ENC (without encoder)
Level 1
without brake (default)
Level 1
very weak brake for condominium GHT9 and medium for industrial
2x
- BRAKE
Level 2
brake with 30% torque
Level 2
weak brake for condominiums and strong for industrial
3x
- BRAKE
Level 3
brake with 60% torque
Level 3
medium brake for condominium and very strong for industrial
(default).
4x
- BRAKE
level 4
brake with 100% torque
level 4
strong brake for condominium - not applicable for industrial
5x
- Enables the SOFT STOP function (DO NOT ENABLE IN DZI MODEL)
6x
- Disables the SOFT STOP function
7x
- Enables the PASS AND CLOSE function of the photocell
8x
- Disables the PASS AND CLOSE function of the photocell
9x
- BOT A works as "open-to-close" (just like on KXH boards), BOT F just stops and closes.
10x
- BOT A only to open, and BOT_F only to close after
releasing
the contact.
11x
- Enables the HALL limit switch sensor
12x
- Disables the HALL limit switch sensor, working only the FF, CM and FA terminals of the Reed Switches.
13x -
Reset, puts all settings to the original factory state, including route (default). Note: Does not erase controls.
Putting into Operation
•
GHT line with encoder, to put the system into operation, follow the following 2 steps:
1 - Gate
Set
DIP 2
to
OFF
, ENC (WITH ENCODER) and
DIP 3 to
LV /PS (LIGHT / HEAVY) according to your application and record a Rossi control to the control panel.
Note: connect the J9 encoder terminal
2 - Setup
Press and hold the ADJUSTMENTS button for 5 seconds until the ST led starts to flash and release the button, then the automatic route recognition process starts at a slow speed; must expect a complete
opening and closing cycle. Check if the brake level meets the application
NOTE:
(VERY IMPORTANT - READ):
1- Until the SETUP step 2 is done, the ST led will flash slowly and the speed will be reduced.
2 - Make sure that the magnets are positioned " Hall Limit Switch sensor" on the sliding line or the "Reed Switch Limit Switch" on the tilting and pivoting line, properly identified (FF and FA) before starting the
recognition process of the route; if there is a need to move the magnet or Reed, repeat step 2 Setup.
3 - The "Photocell" safety device will be inoperative in step 1 and 2.
4 - The Tx, pushbutton or ADJUST button commands have priority over the route recognition process. Therefore, if any of these devices is activated during the recognition process, the system will be
interrupted and the process of step 2 SETUP must be restarted.
5 - In step 2, if the gate is not at the limit switch, the plate moves the gate to a limit switch and then performs a complete opening and closing cycle
6 - If the magnet has to be repositioned, it will be necessary to redo the recognition of the path from step 2 SETUP.
7 - Parameter adjustments must be made with the gate stopped; after adjustment, perform a complete opening and closing cycle by the remote control to confirm the adjustment value.
•
Automator without encoder,
1 - Gate
• Check the FF and FA magnets if they are in the correct position, record a Rossi control and adjust the clutch.
• Set
DIP 2
to
ON
, Ñ ENC (NO ENCODER). To enable soft stop press SET 5X button,
DIP 3
between LV /PS (LIGHT / HEAVY) according to your application.
Malfunction Search
Malfunction
Cause
Solutions
ST led is blinking slowly, the SETUP process was not done.
Do the ''Getting Started'' process
Does not increase speed
Gate is above max weight or locked
Check the weight limit for the drive and movement
of the Gate
Does not start SETUP
Encoder off
Check J9 connector connection and functionality
Automator makes noise and
not movement
Motor connected to wrong voltage
Enter the voltage according to the motor label
Ÿ The starting capacitor is not connected to the CAP
terminal of the control panel / damaged capacitor
Ÿ Insert starting capacitor according to the voltage and
power of the motor / replace capacitor
Does not start SETUP, led FF
or
FA intermittent blinking
Magnet polarity is reversed
Correctly position the FA and FF magnets
Wires V and W are reversed
Reverse the position of the V and W wires
The gate is outside the route limit
start the SETUP process with the gate in the middle of the
route
Magnet polarity is reversed
Correctly position the FA and FF magnets
Setup does not finish
Wires V and W are reversed
Reverse the position of the V and W wires
The remote control, SET or LEARN buttons were
triggered before the end of the process.
Start the SETUP process without pressing the buttons until
complete.
Automator does not turn on:
ST led intermittently blinking
FS function enabled and SIA 30FS photocell not installed
correctly
• Check Installation of FS mode in item 6 of the manual.
SIA 30FS photocell with busy beam (obstacle)
• Unclog the beam and check wiring
Gate slamming into frame /
leaving the limit switch
The position of the limit switch has been changed after
SETUP
Check the position of the magnets and carry out the
process of Putting into Operation
The acceleration, deceleration, brakes or
Adjust the brake levels according to the weight
speeds are high for the application
and automator model
Gate closing after
pass the car
Ÿ PASS AND CLOSE function enabled with photocell installed
with the pause time at 0 sec.
Disable the function by pressing the adjustment button 8
times.
FF and FA led does not light
and does not
STOP the gate
Hall limit switch, has been disabled in the control unit
Press the SET button 11x to enable the sensor end of
hall sensor
Does not make soft stop
DIP 2 in ON function without encoder enabled
Press SET button 5x to enable soft stop
Pg.06
ADJUSTMENTS
ADJUSTMENTS