Table 6, Table 7, and Table 8 provide a listing of the Contact ID (CID) codes
used to communicate with the CMS.
Table 6: Event Codes: Contact ID and SIA - Burglary and Fire
Burglary and Fire Event/Restore
Description
CID
Description
CID
Medical Alarm (Restore)
R100
Shorted (Event)
E142
Emergency Alarm (Event)
E101
Wired Tamper (Event)
E144
Fire (Event)
E110
Wired Tamper (Restore)
R144
Fire (Restore)
R110
Any Zone Trouble (Event)
E380
RF Panic (Event)
E120
Any Zone Trouble (Restore)
R380
Alarm – 24-hour Silent (Event)
E122
RF Supervisor (Event)
E381
Alarm – 24-hour Silent (Restore) R122
RF Supervisor (Restore)
R381
Burglary (Event)
E130
RF Tamper (Event)
E383
Burglary (Restore)
R130
RF Tamper (Restore)
R383
Alarm – 24-hour Audible (Event) E133
RF Low battery (Event)
E384
Alarm – 24-hour Audible
(Restore)
R133
RF Low battery (Restore)
R384
Open (Event)
E141
Table 7: Event Codes: Contact ID and SIA - Arming Events
Arm and Disarm Events
Description
CID
Description
CID
Duress
E121
Key Switch Disarm
E409
Disarm
E401
Key Switch Arm Away
R409
Arm Away
R401
Forced Arm Away
R423
Alarm Cancel
E406
Table 8: Event Codes: Contact ID and SIA - System Events
System Events
Description
CID
Panel Remote Tamper (Event)
E137
Panel Remote Tamper (Restore)
R137
Panel Trouble