AY-B86x0
Anti-Vandal Outdoor Fingerprint Readers
User Manual
1
1.
Introduction
The AY-B86x0 series are biometric fingerprint and RFID card reader
with a compact design, which is suitable for installing on a door
frame. The USB power supply and debug make operations simple.
The reader IP65 certified for outdoor use.
Using AxTraxNG, you can register and delete users (see the
AxTraxNG™ Software Installation and User Manual
). Alternatively, you
can use master cards to register and delete users while in an offline
state.
The standard Wiegand output seamlessly connects to the third-party
access controllers.
The reader comes in two models:
AY-B8620 – 125 kHz EM RFID card reader
AY-B8650 – 13.56 MHz MIFARE card reader
Figure 1: AY-B86x0
2.
Installation
2.1
Mounting
1.
Using the back panel as a guide, drill two holes for mounting
the back plate onto the surface (Figure 2).
Figure 2: Wall Mounting
2.
Insert a suitable wall plug into each screw hole.
3.
Drill a 10-mm (7/16”) hole for the cable.
4.
Screw the back plate onto the wall.
5.
Connect the reader to the controller (see Section
2.2). A linear
type power supply is recommended.
6.
Attach the reader to the back plate and secure the reader to the
back plate with the provided security screw and tools.
2.2
Wiring
To connect the unit as a reader to an access control unit:
1.
Select the appropriate connections according to Table 1.
Table 1: Wiring the Unit as a Reader to a Control Panel
Function
Cable Color
Description
Power
Red
12 VDC
Black
GND
Tamper Alarm
Brown
Tamper
Orange
Tamper
Wiegand
Output
Green
Wiegand DATA0 Output
White
Wiegand DATA1 Output
Blue
Wiegand switch
Black
GND
Pulse Signal
Light brown
RS-485B/GND
Light Blue
RS-485A/pulse signal (3.3 V)
2.
Prepare the controller cable by cutting its jacket back about
3 cm (1¼") and strip the insulation from the wires about 1.3 cm
(½").
3.
Splice the reader’s pigtail wires to the corresponding controller
wires and cover each joint with insulating tape.
4.
Trim and insulate the ends of all unused conductors individually.
Do not short any unused wires together.
•
The individual wires from the reader are color coded according the
Wiegand standard.
•
When using a separate power supply for the reader, this supply
and that of the controller must have a common ground.
•
The reader’s cable shield wire should be preferably attached to an
earth ground, or a signal ground connection at the panel, or the
power supply end of the cable. This configuration is best for
shielding the reader cable from external interference.