Programming Cards and Tags
24
CP-R25 Hardware and AS-B01 Software Manual
Refer to the specific reader’s installation manual for a detailed explanation of
the various options.
5.2.1
Sector Reader Configuration Cards
A Sector Reader Configuration card allows you to create a configuration card,
which is used to configure the various sector readers such as the AY-W6260,
AY-W6360, AY-Q6260, and AY-Q6360 units.
To prepare a Sector Reader Configuration card:
1.
Select the
Sector Reader
tab.
2.
Select the applicable
Operation Mode
, either
Sector
or
Card Serial
Number (CSN)
.
3.
From the
Operation Type
dropdown menu, select
Program
Configuration Card
.
4.
In
Card Type
, select either
Mifare
®
1 K
or
Mifare
®
4 K
.
5.
From the
Transmit Format
dropdown menu, select the applicable
transmission format.
6.
For
Sector
operation mode, select values for the
Sector Number
,
Block
Number
, and
Byte Number
fields in
ID Location.
7.
Ensure that
Operations
is set to
Program Card
.
8.
Define the
Led and Buzzer Control
behavior by selecting or clearing the
Enable Led
and
Enable Buzzer
checkboxes.
9.
For readers with a keypad:
a.
Select the
Keypad
checkbox.
Additional keypad options appear.
b.
In the
Backlight options
dropdown menu, select the backlight
behavior.
c.
From the
Transmit Format
dropdown menu, set the keypads’
transmission format.
10.
For
Sector
mode, enter the KeyA to be used by the reader as the unique
KeyA for the organization or site in both the
Reader KeyA
and the
Confirm Reader KeyA
fields.
The KeyA number is hidden by "*" characters, so write down the new key
and keep it in a safe place to avoid exposing this secret key to unauthorized
personnel. The KeyA value is entered as a 12 hexadecimal digit. The default
KeyA is FFFFFFFFFFFF.
11.
Place a blank Mifare
®
card or a card previously configured as a
Configuration card on the CP-R25 Desktop Programmer antenna area.
12.
Click
Start
to begin programming the Mifare
®
card.
On completion, a message appears in the Message Log area to verify that