MEASURING AND SWITCHING DEVICE 

ROSSMA IIOT-AMS ANALOG 

 

 

 

 

 

OPERATION MANUAL 

 

 

 

ROSSMA  IIOT-AMS  Analog  is  used  for  autonomous  data  measurement  from  control  and 

measuring  devices  with  current  interface  4-20mA  and/or  with  resistive  interfaces  of  pt1000, 

Ni1000, TK5000 type with subsequent transmission of received data in LoRaWAN and/or NBiOT 

network. 

The ROSSMA IIOT-AMS Analog switching device provides non-volatile operation of control and 

measuring devices. 

Summary of Contents for IIOT-AMS

Page 1: ...data measurement from control and measuring devices with current interface 4 20mA and or with resistive interfaces of pt1000 Ni1000 TK5000 type with subsequent transmission of received data in LoRaWAN...

Page 2: ...RaWAN ROSSMA IIOT AMS ANALOG ROSSMA IIOT AMS ANALOG Ex single channel LoRaWAN ROSSMA IIOT AMS ANALOG ROSSMA IIOT AMS ANALOG Ex multichannel NBiOT ROSSMA IIOT AMS ANALOG ROSSMA IIOT AMS ANALOG Ex singl...

Page 3: ...HM 5 FUNCTIONALITY 5 MARKING 6 DATA ON CERTIFICATION 7 2 TECHNICAL CHARACTERISTICS 8 3 WORKING WITH THE SWITCHING DEVICE 10 CONTACTS DESCRIPTION 10 INDICATORS AND BUTTONS 10 INITIAL START UP 11 4 COMM...

Page 4: ...er switching device and defines installation and connection procedure as well as control commands and functional description The manual is intended for specialists familiar with the installation rules...

Page 5: ...ce can have single channel and multi channel modifications The multi channel modification of the switching device can have up to 8 inputs The switching device supports two operation modes For operatio...

Page 6: ...of ROSSMA IIOT AMS Analog 110 days 220 days 2 5 years 10 years If the Request Confirmation parameter is enabled the switching device will send the next package only after receiving delivery confirmati...

Page 7: ...in the form of application on the housing which contains information on the product name There is a label with the device number for its identification from the manufacturer in the housing This numbe...

Page 8: ...peration in Explosive Environments LPWAN standard Switching device model Housing protection degree Quantity of inputs and outputs Switching device version ROSSMA manufacturer OUI registered in IEEE Re...

Page 9: ...RU868 EU868 IN865 AS923 AU915 KR920 US915 KZ865 any on the basis of EU868 Activation method in LoRaWAN network ABP OTAA adjustable Communication Period Adjustable in LoRaWAN network LoRa antenna type...

Page 10: ...IP68 for multichannel model Mounting The housing has holes for stationary fastening to any surface The housing can be completed with a plate with for DIN rail adapter it is specified when ordering The...

Page 11: ...inals for connection and simultaneous operation of up to 8 CMD To switch from warehouse mode to active mode use a jumper marked On located near the built in battery It is possible to connect external...

Page 12: ...of Warehouse mode before it can be used To switch from Warehouse mode to Active mode install the jumper on both terminals On The switching device supports two methods of activation in the LoRaWAN net...

Page 13: ...s C Data package format for ROSSMA IIOT AMS ANALOG switching device single channel The total amount of the transferred package 6 10 byte Example DD02EE0EA608CA0E0114 Byte 0 0xDD package type 0xDD Pack...

Page 14: ...ON AND PROGRAMMING The switching device is supplied with built in firmware that enables the switching device to operate with the characteristics specified in this document The switching device is prog...

Page 15: ...ULES ROSSMA IIOT AMS switching devices shall be stored in the factory package in heated rooms at temperature from 5 to 40 and with relative humidity not more than 85 The switching devices can be trans...

Page 16: ...28 08 2019 15 6 DELIVERY SET The standard delivery set of ROSSMA IIOT AMS Analog switching device includes ROSSMA IIOT AMS Analog switching device in factory packaging 1 pc Sealed outlet installed in...

Page 17: ...Manufacturer shall not be liable for defects caused by normal wear non compliance with the Manufacturer s requirements in terms of storage installation operation or operating conditions inadequate usa...

Page 18: ...www rossma ru www rossma ru Operation manual LLC ROSSMA 2019...