ROSSMA IIOT-AMS ANALOG/
OPERATION MANUAL
7th revision 28.08.2019.
6
•
Luminance sensors;
• Humidity sensors;
• Current and voltage/battery sensors.
The switching device is class A device (LoRaWAN classification) and provides the following ̆
functionality:
•
Support of both active and passive control and measuring devices;
•
ADR (Adaptive Data Rate) support
•
Wireless configurable LoRaWAN activation type in LoRaWAN network - OTAA, AVP;
•
Configurable communication period from 1 minute and more (configured remotely over
LoRaWAN network). The default value is 1 times per hour;
•
Support for sending confirmation packages (configurable)
•
Two operating modes "Active ̆" and "Warehouse";
•
Frequency plan: EU-868\RU-868 (to switch remotely in LoRaWAN network). Default is
RU- 868;
•
Temperature measurement;
•
Measurement of built in battery charge in %.
MARKING
The switching device marking is made in the form of application on the housing, which
contains information on the product name.
There is a label with the device number for its identification from the manufacturer in the
housing. This number also serves as ID with the ratings of a particular switching device.
The switching device certificate contains the following information:
•
Product name;
•
Product version information;
•
Keys required to log in the switching device in the network;
•
DevEUI;
•
Month and year of production.
The label with the device number is located in three places - on the switching device
housing, on the electronic board inside the housing and on the packing box (the first digits before
the separator: the device number - XXXXXXXXXX).
It is possible to identify the device certificate by the device number in the column
"identifier" - the last digits in the number after the separator.
The ID is XXXXXXXXXXXXXXXXXXXXXXXXXX - XXXXXX. The first part of the identifier is the
part number and the second part is the serial number of the switching device. Interpretation of
part number: