Starting up
23
6.3
Settings
6.3.1
Top position sensor
The "top position" sensor is located on the inner side of the master lifting unit. It
should be adjusted so that the lift platform stops
before
the hydraulic cylinders
reach the upper end position.
6.3.2
Euro Stop sensor
The sensors for the Euro Stop are located on the outer sides of both lifting units.
They are to be adjusted so that the lift platform stops if the distance between the
upper edge of the underframe and the lower edge of the upper frame (h) amounts
to at least 120 mm to max. 250 mm.
6.3.3
Intermediate stop sensor
The sensor for the intermediate stop function is located on the inner side of the
slave lifting unit.
Fig. 6-1 Sensor for top position
Fig. 6-2 Euro Stop sensor
Fig. 6-3 Euro Stop distance
Fig. 6-4 Intermediate stop sensor