d0
45
3
0
.f
m
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 914 Series
Edition 2 / Rev. 0
12-20-00
page 23
January 01/2010
8) Checking the wastegate flap
General note
.
Checks
The following checks must be carried out:
WARNUNG
NOTICE
Damage to the bowden cable is not permissible. If only
1 flexible wire of the bowden cable is abraded, the ca-
ble must be replaced. See 78-00-00 of the Heavy
Maintenance Manual.
Step
Procedure
1
Check the bowden cable of the wastegate actuation (1) for mechanical dam-
age or wear.
2
Check the bowden cable suspension and spring.
3
Check the adjustment of the wastegate flap.
NOTES:
When the engine has been shut down, the servo motor al-
ways runs to closed position.
This also applies when the TCU is switched on. The servo
motor moves approx. 1/2 revolution and then remains in
closed position.
In this position, the wastegate flap must be completely closed. If necessary,
readjust using the adjusting screw (2). See 78-00-00 of the Heavy Mainte-
nance Manual.
4
Check the wastegate lever (3) for free movement.
NOTES:
If it does not move freely, lubricate the axle (lubrication hole)
of the wastegate with LOCTITE Anti-Seize 8151, ROTAX
part no. 297434.