d0
452
6.
fm
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 914 Series
Edition 2 / Rev. 0
05-20-00
page 17
January 01/2010
17.) Checking the V-belt tension
On configurations with auxiliary generator, check the
attachment and the V-belt tension.
X
12-20-00
sec. 6)
18.) Electric fuel pumps
Check the electric fuel pumps.
every 1000 hr.
MM II
(Heavy)
73-00-00
sec. 3.4.6)
Replace the main fuel pump.
every 1000 hr.
IM
sec. 14.4)
19.) Engine test run
Observe the safety instructions!
Start the engine and run to operating temperature.
Limits see Operators Manual 914 series.
Ignition check at _____ rpm engine speed.
Speed drop without ignition circuit:
A (Off)___________rpm
B (Off)___________rpm
A/B (difference)________rpm
After engine test run, re-tighten the oil filter by hand
(only at cold engine).
Checks for leaks.
X
12-20-00
sec. 8)
General note
All Service Instructions and Service Bulletins are
complied with.
X
Returning engine to service
On the engine identified as per point 5, on the _____________________ the________hr.
Check at______hr. (TSN___, TSO___) was carried out according to recommendations of the engine manufac-
turer and was recorded in the Engine Log book.
Location, Date_______________________
Inspector___________________________
Aircraft mechanic_____________________
Certificate No.______________________