Pressure test
To ensure the System has no leakage, remove the pressure cap from the expansion tank.
Then attach the pressure tester and pump the system until the pressure manometer
shows 1.2 bar (18 psi). After min. 1 minute, there should be still 1.2 bar (18 psi) pressure
in the system.
• Check the efficiency of the coolant radiator and its proper sealing between cowling and
radiator.
• Check the proper flow between expansion tank and overflow bottle.
• Ensure that no ram is induced onto the overflow bottle vent line.
• Check efficiency of air duct and proper air flow through the duct and around cylinders.
• Consider cold (winter) and hot (summer) conditions in ground and flight testing.
• Check proper dampening of the water radiator and stressfree installation and proper
sealing.