SYSTEM LIMITATIONS
Operating limits
Refer to latest issue of the Operators Manual.
Modifications
Modifications of the system by the OEM (e.g. cut the exhaust) may be done, if following re-
quirements are met:
• All exhaust parts added by the OEMs are decoupled (weight and vibration) from the ex-
haust provided
• Exhaust back pressure must not exceed following limits:
System Limit
Min.
Max.
Exhaust back pressure
(ambient pressure: 1000
mbar)
155 mbar
180 mbar
Exhaust back pressure
(ambient pressure: 900
mbar)
175 mbar
205 mbar
Exhaust back pressure
(ambient pressure: 800
mbar)
195 mbar
230 mbar
Exhaust back pressure
(ambient pressure: 700
mbar)
215 mbar
255 mbar