SYSTEM DESCRIPTION
For a detailed System description refer to the latest issue of the Operators Manual.
SYSTEM LIMITATIONS
Operating limits
Refer to latest issue of the Operators Manual.
m
WARNING
Non-compliance can result in serious injuries or death!
The lubrication system must be designed such that the permissible operating tempera-
tures and maximum values are not exceeded.
Pressure limits
Following measurements must be exceeded when operating the engine at full throttle:
System Limit
Min.
Max.
Crankcase pressure
relative to ambient pres-
sure at full load = 5800 rpm
(Oil temperature 90 °C
(194 °F))
Ambient pressure
400 mbar
Pressure loss in suction
line
-
200 mbar
Effectivity: 915 i A Series