BRP-Rotax
INSTALLATION MANUAL
Figure 5.5: Rear view
22
Ignition housing
23
Electric starter
24
Water pump housing
25
Engine suspension frame (ring mount)
26
Turbocharger assy.
27
Solenoid valve (PCV)
28
Fuel pressure regulator
SYSTEM LIMITATIONS
Operating limits
Refer to latest issue of the Operators Manual.
Installation
position
The oil system, fuel system and the cooling system are unsuitable for upside-down / in-
verted installation of the engine.
System Limit
Min.
Max.
Static roll angle ß
40°
The oil level should be in the upper half (between the “50%” and the “Max.” mark) and
should never fall below the “Min.” mark. For the oil level measuring procedure refer to the
latest version of the respective operators manual.
Page 6
December 01 2017
Effectivity: 915 i A Series
Edition 0/Rev. 0
Summary of Contents for 915 iS 3 A