MDR-42
Dimming Control
ROTEC technology
- 80 -
10.8. Parameter file
The parameter file for Dimming Control is „dimming.ini“
All necessary definations for Dimming Control are in this INI-file.
Structure of an defination : a. [x]
x:=Section
b. Count=x
x:=number of entries
c. Val=x
x:=Werte
10.8.1. Characteristic actual temperatue value
This characteristic adjust the the actual temperature value
Input is the value of the analogic input in digits
Output is the according temperature in °C
Curve:
[TEMPERATUR]
Input
Output
Count=8
Val=-110,0;-55,0
// Device value = -110,0 / Temperature = -55,0 Grd Celsius
Val=-50,0;-25,0
Val=-1,0;-0,5
Val=0,0;0,0
Val=1,0;0,5
Val=50,0;25,0
Val=250,0;125,0
Val=0,0;0,0
10.8.2. Characteristic DA-converter
This characteristic adjust the output voltage of the DA converter for the backlight inverter.
Input = Sollwert [%] / output = Digits DA converter
Curve :
[DAWANDLER]
Input
output
Count=3
Val=0,0;31,0
// Setpoint = 0,0 % / Digits for DA converter = 31,0
Val=100,0;0,0
Val=0,0;0,0
10.8.3. Characteristic ambient light / brightness backlight
This caracteristic adjust the value for brightness of backlight depending on the ambient light sensor
Input = ambient light [Lux] / output = value brightness %
Curve:
[LUXSOLLPROZENT]
Input
Output
Count=3
Val=0,0;15,0
// Brightnes = 0,0 Lux / Setpoint = 15,0 %
Val=1950,0;100,0
Val=0,0;0,0
Summary of Contents for MDR-42
Page 1: ...MDR 42 Ruggedized POI PC Display User Manual you ROTEC ...
Page 2: ......
Page 14: ...MDR 42 Important Safety Information ROTEC technology 12 ...
Page 28: ...MDR 42 Technical Data ROTEC technology 26 9 3 Mechanical dimensions ...
Page 42: ...MDR 42 Technical Data ROTEC technology 40 9 8 BLOCK DIAGRAM ...