Dimming Control
MDR-42
- 87 -
ROTEC technology
10.9.1.2. Dimming Control
Application
Message
Description
WM_SYSZUS
System state ( wParam = state ) / ( lParam = Errors )
WM_TEMPBRIGHT
Temperaure and Brightnes
wParam = Temperature [Grad Celsius]
lParam = Brightnes [Lux]
WM_TEMPCPU
Temperature CPU
wParam = Temperature CPU [Grad Celsius]
10.9.1.3. System state
wParam
Bit Bedeutung
0 1 = Dimming Control is running
1 1 = error
2 1 = Backlight is on
3 1 = Fan group 1 is on
4 1 = Fan group 2 is on
5 1 = Warning Temperature to hight
6
7
8 Watchdog is enabled
9 Supervisior for application software is enabled
10 Fangroup 1 is enabled
11 Fangroup 2 is enabled
12 Backlight fix is enabled
lParam
Bit Bedeutung
0 1 = error device ADC
1 1 = error device temperature
2 1 = error device ambient light
3 1 = error hardware initialization
4
1 = error reading hostname in „dimming.ini“
19 1 = backlight off because of low temperature
20 1 = backlight off because of high temperature