Introduction
The TriStar J18 AT automatic turnstile is designed for use in high volume traffic areas to
control pedestrian traffic. Any type of access control or ticketing system can be used
to activate the turnstile. The turnstile is operated using a DC brushless motor which
ensures a smooth operation and the inbuilt encoder guarantees exact positioning of
the arm. When connected to the fire alarm or other emergency system the active
arm drops allowing fast exit from the building. During a power failure the arm drops
and will automatically reposition itself when the power is restored.
2.
Technical Specifications
Model No
TriStar J18 AT
Throughput
25 users per minute
Channel width
550-600 mm
Duty cycle
100%
Operating input
Potential free N/O
MCBF
300 million operations
Safety devices
Arm drops in emergency
IP rating
IP 55 standard
Signal time out
Adjustable up to 20 seconds
Power supply
- 10%
Motor voltage
24vdc
Power consumption
50W
Working environment
-
30
℃
~+
70
℃
Relative humidity
95%
3.
Standard features
3.1
Easy set up using the LED display.
3.2
Accurate positioning using the encoder.
3.3
The control panel shows the status of all key components.
3.4
Multiple input and output ports, can be configured to user requirements.
3.5
When the arm is returning to the default position it slows so that there is no
mechanical force on the internal components.
3.6
Suitable for both Indoor and outdoor.
3.7
The control panel indicates the current status.
3.8
The rotation speed of the arm while entering the turnstile can be adjusted.
3.9
If the arm is forced without presenting a card the arm locks for 4 seconds.
3.10
The turnstile can be opened by two input signals (signals can be input by access
controller, push button or other equipment).
3.11
Indicator lights: When the turnstile is ready to read the card, the light in the middle will
be yellow. After reading card the upper blue light will come on. If someone tries to
push the arm without permission, the red light will come on.
3.12
Single direction or bi direction is optional.
3.13
In an emergency or power failure the active arm will drop. The control panel can be