background image

 

Parameter 

Description 

Value 

 

Valu

 

P-00    

Example 

      

      

P-01    

Counting function selection 

0       Disable  

1      Enable 

P-02   

To allow access in entry 

direction 

0        Disable 

1         Enable 

P-03    

To allow access in exit 

direction 

0       Disable 

1     Enable 

P-05    

Reserved 

   

 

         

P-06    

Entry control by  

0     Swiping card 

1     Free wheel 

P-07     

Exit control by 

0      Swiping card 

1      Free wheel 

P-08     

Rotation speed of arm during 

self-check at startup 

Value is 0-100, the larger the value, faster 

the speed, default 70 

P-09    

Rotation speed when 

operating the turnstile 

Value is 0-70, default 50 

P-10    

Reset speed when the bar is 

off center 

The value is 0-50. The larger the value, the 

more accurate the accuracy, but the 

greater the jitter, default 34 

P-11   

Speed setting after the arm 

locked 

The value is 0-70, default is 40 

P-12  

Recovery time of the first lock 

(recovery time of the first forced 

lock l: the recovery time of the 

second lock is 4 times of the first, 

and the recovery time of the N 

times lock is (n-1)*4 times of the 

recovery time of the first lock ).

 

Maximum value 20S, defaulted  2S 

P-13  

Waiting time after swiping 

card 

Maximum value 20S, default 8S 

P-14 to P-24  Reserved 

 

 

 

 

P-25    

Zero setting 

 

 

 

 

P-26     

Program version selection  

 

 

 

 

 

 

8.3

 

Interface instruction 
 

Summary of Contents for TRISTAR J18 AT

Page 1: ...TAR J18 AT TURNSTILE Instructions V11 19 Unpacking the turnstile First remove the top cover of the wooden crate then the side cover The turnstile inside the crate can now be pulled out of the crate Do...

Page 2: ...environment 30 70 Relative humidity 95 3 Standard features 3 1 Easy set up using the LED display 3 2 Accurate positioning using the encoder 3 3 The control panel shows the status of all key component...

Page 3: ...nter can be connected to count the number of people passing through the turnstile 4 3 RS485 communication PC command through serial port 4 4 Audible and or visual alarm to indicate attempted forced en...

Page 4: ...4 7 Z3D001A Control Panel...

Page 5: ...a self test the turnstile is now ready set the parameters 8 1 Main board control buttons and LED display Figure 11 Digital Tube 8 2 Parameter set up For example If you wish to change parameter P 01 c...

Page 6: ...e turnstile Value is 0 70 default 50 P 10 Reset speed when the bar is off center The value is 0 50 The larger the value the more accurate the accuracy but the greater the jitter default 34 P 11 Speed...

Page 7: ...status indicator blue light ZYL status indicator yellow light IO5 Alarm interface ALM Alarm output signal ALM Alarm output signal ALM GND IO7 Forward reversed counting Arm drop signal input B1 Reserv...

Page 8: ...wear if OK add lubricant Arm is slow returning to start position Adjust tension springs Emergency arm drop off not working or arm won t lock in position when power on Adjust the position of the relea...

Page 9: ...Dimensions NOTE The concrete pad should be 20Mpa min 150 mm thick cured for 7 days on a suitably compacted foundation Hold down anchors 4 to be 12mm dia x 100mm into the concrete Control panel in Entr...

Page 10: ...al cleaning wipe down exterior surfaces with thinners then polish with stainless steel polish If outdoor polish every 3 months In wet environments daily cleaning with water polish every 4 weeks to pre...

Page 11: ......

Reviews:

Related manuals for TRISTAR J18 AT