background image

10

RLC-1080 

Power Conditioner

Model Number and  

Serial Number Screen

This screen displays the model number and serial 
number of your unit. Please have this information 
available any time you need to talk with Rotel 
Technical Support, as well.

����������������

����������������

Internet Address Screen

This screen provides the world-wide Internet 
Web address for Rotel. 

����������������

INPUT FREQUENCY;  

OUTPUT FREQUENCY Screen

This screen shows the AC line frequency of the 
power coming from the wall power outlet and 
the AC line frequency of the power being sup-
plied to the connected devices.

����������������

����������������

At times, the frequency values on this screen may 
not match. This is due to the fact that separate 
circuits are used to make frequency measure-
ments, and there is a time delay between the 
two circuits for updating this status screen. This 
condition is normal.

Note:

 The display will revert to the default 

SOURCE; EST RUNTIME screen after about 
30 seconds of inactivity. The default screen 
can be changed. See the “Setting the Default 
Screen” section of this manual.

Connecting the Components

WARNING:

 Do not make telephone, cable, 

Ethernet, antenna, electrical, or ground 

system 

connections during a lightning storm. Failure to 
comply may result in personal injury or death.

The RLC-1080 has four groups of power outlets. 
Each group has specialized filtering and surge 
protection that are specifically designed for 
certain type of components. It is recommended 
that you connect your A/V components to the 
power outlets that are designed for that type of 
unit. For more information see the 

AC Power 

Outlets

 section of this manual.

Connect the ground connector of each component 
in the system to the 

SYSTEM GROUND

 terminal 

on the RLC-1080. This will eliminate “ground 
loops”  thus prevent the audible hum that they 
might otherwise produce.

Setting Up the RLC-1080 

Using the front panel 

SETUP

 and 

Arrow Up/

Down

 buttons, you can configure or turn on/off, 

various functions of the RLC-1080. Pressing the 

SETUP

 push button will display these functions 

in the following order:

1.  Audible Alarm
2.  Sensitivity, Display Dimmer
3.  LED Dimmer
4.  Go To Battery If <XX Volts,  

Go To Battery if >XX Volts

5.  Outlet Delay1
6.  Outlet Delay2
7.  Low Battery Warning
8.  Battery Replacement Date
9.  Do Quick Selftest
10. Do Runtime Calculation
11. Display Beep Test
12. Screen Saver On/Off, or Reset to Default

AUDIBLE ALARM Setting 

When set to 

ON

 this provides an audible tone 

whenever the unit detects a problem with itself, or 
with an externally connected battery pack. In the 
OFF setting, the audible tone is silenced.

����������������

������������������

SENSITIVITY Setting

Press the 

SETUP

 button to advance to the Sensi-

tivity function. This feature adjusts how the RLC-
1080 reacts to abnormal power input voltage 
or momentary power fluctuations. It allows you 
to adjust the sensitivity to 

LOW

MEDIUM

 or 

HIGH

  using the 

SETUP

 and 

Up/Down Ar-

row 

buttons. The Sensitivity adjustments have the 

following values:

Summary of Contents for RLC-1080

Page 1: ...RLC 1080 Power Conditioner Owner s Manual To register your purchase now go to www rotel com ...

Page 2: ...bend in the power cords which may break the wire strands of the cord Although this device provides protection against electrical surges when connecting an outside antenna or cable system to devices connected to this device ensure the antenna or cable system is grounded so as to provide additional protection against voltage surges and static charges in accordance with Section 810 of the National El...

Page 3: ...3 English Front and Rear Panel Controls and Connections ...

Page 4: ...ections 3 About Rotel 4 Getting Started 4 Features 5 Parts List 5 A Few Precautions 5 Power Capacity 5 Placement 5 Front Panel 6 ON BATTERY Status Indicator 1 6 DELAYED 1 Status Indicator 2 6 DELAYED 2 Status Indicator 3 6 REGULATING Status Indicator 4 6 Vacuum Fluorescent Display 5 6 OVERLOAD Status Indicator 6 6 FILTERING Status Indicator 7 6 LINE OK Status Indicator 8 6 LOW BATTERY Status Indic...

Page 5: ...r cause the building circuit breaker to trip Parts List The RLC 1080 Power Conditioner includes the parts listed below If any items are missing please contact your authorized Rotel dealer 1 Power Conditioner with Battery Backup bat tery pack included 1 Front Display Panel Bezel 1 Input Power Cord 3 Coaxial Patch Cables 1 DC Trigger Cable 1 PowerChute Personal Edition Software CD 1 USB Interface Ca...

Page 6: ...to maintain safe voltage conditions for the connected components or the unit is operating on battery power due to a power outage or extreme voltage level conditions LOW BATTERY Status Indicator 9 When lit orange this indicates the Battery Pack charge level is low This should occur only after the RLC 1080 has been running on battery power for a period of time The user can set the unit so this indic...

Page 7: ... reset the Circuit Breaker simply push the button in Caution When resetting the Circuit Breaker push the button in quickly and release it Do not hold the Circuit Breaker button in Doing so may result in equipment damage SYSTEM GROUND Screw o Provides for the connection of grounding wires from all of your equipment Grounding all your equipment to a single terminal prevents ground loop problems that...

Page 8: ...lock the fan Connecting the Battery The RLC 1080 is shipped with front bezel of the unit unattached and with the internal battery pack disconnected Connect the internal battery pack and attach the front bezel as follows 1 Remove the battery retaining bar 2 Push the Battery Wire Connector into the hole located at the left of the Battery Pack Check to be sure that the connector is securely connected...

Page 9: ...the AVR is active SYSTEM LOAD XXXW LOAD XXX This screen shows the power load of the connected equipment in watts as well as a percentage of the total allowable load connected to the unit Loads less than 5 of the rated power 50 watts are displayed as 5 EST RUNTIME XHRS FUEL XXX This screen shows the Estimated Runtime in hours as well as the Fuel capacity of the internal battery pack as a percentage...

Page 10: ... designed for certain type of components It is recommended that you connect your A V components to the power outlets that are designed for that type of unit For more information see the AC Power Outlets section of this manual Connect the ground connector of each component in the system to the SYSTEM GROUND terminal on the RLC 1080 This will eliminate ground loops thus prevent the audible hum that ...

Page 11: ...Y IF XXXV Setting Display example not shown This lets you set a low voltage threshold for the unit If the power input voltage goes down to the level set on this display screen the RLC 1080 switches to Internal Battery power The input voltage when this happens can be set from 90 to 100 volts OUTLET DELAY1 and OUTLET DELAY2 Setting Only the Outlet Delay1 display screen is shown This lets you set the...

Page 12: ...press the Status button until the desired screen is displayed Then press and hold the Status button down until the screen displays CURRENT SCREEN IS SAVED AS DEFAULT Troubleshooting The VFD screen will display any faults or warn ing conditions that occur along with a message explaining what action to take If ever in doubt as to what action to take please contact your authorised Rotel dealer or Rot...

Page 13: ... Car tridge part RBC63 canbeorderedfromyourau thorized Rotel dealer or Rotel Technical Support at techsupport rotel com or 800 370 3741 Limited Warranty Rotel warrants this product to be free from defects in materials and workmanship for a period of two years from the date of purchase Rotel s obligation under this warranty is limited to repairing or replacing at its own sole op tion any such defec...

Page 14: ... 90 Capacity 8 hrs Battery Service User replaceable Hot swappable Battery Life 2 5 Years Depending on use environment and temperature Battery Runtime 20 minutes half load or 7 5 minutes full load Actual runtimes are determined by load battery charge level battery health and quantity of batteries installed SURGE PROTECTION Let Through Voltage Rating 40V Data Line Protection Jacks RJ45 COAX 3 pair s...

Page 15: ......

Page 16: ...rd Street North Reading MA 01864 2699 USA Phone 1 978 664 3820 Fax 1 978 664 4109 Rotel Europe Dale Road Worthing West Sussex BN11 2BH England Phone 44 0 1903 221 761 Fax 44 0 1903 221 525 Rotel Deutschland Vertrieb B W Group Germany GmbH Kleine Heide 12 D 33790 Halle Westf Deutschland Tel 05201 87170 Fax 05201 73370 E Mail info bwgroup de www rotel hifi de www rotel com ...