8

RLC-1080 

Power Conditioner

Installation

Placement

Caution:

 The RLC-1080 weighs approxi-

mately 60 pounds. Two-people should work 
together when the unit is being moved. Lift the 
RLC-1080 carefully by firmly grasping both 
sides of unit in the middle. 

Failure to use 

caution and proper procedures when 

lifting or moving the unit may result 

in personal injury and/or equipment 

damage.

Place unit on a solid, flat surface that is capable 
of supporting at least 60 lbs. 

Note:

 Avoid placing other components directly 

on top of or behind the unit. Leave at least one 
inch of space on all sides to allow for proper 
air ventilation. Do not block the fan.

Rack Mounting

The RLC-1080 can be mounted in a standard 19” 
rack. Rack-mounting hardware is provided. 

1.  Install the rack-mount rails. (See the installa-

tion sheet located in the box containing the 
rack-mount rails.)

2.  Install the rail cleats. (See the installation sheet 

located with the cleats in the box marked 
“Accessories.”)

3.  Install rack-mount ears. (OPTIONAL — See 

the installation sheet located with the cleats 
in the box marked “Accessories.”) 

Note:

 

Rack-mount ears are not required. Their only 
function is to fasten the unit to the front of the 
rack and prevent front-to-rear movement.

Caution:

 Rack-mount ears should 

NEVER

 

be used alone to support the unit. Rack-mount 
rails must always be used to support the unit’s 
weight when rack-mounting.

4.  Slide the unit into the rack so that the cleats 

mounted on the side of the unit fit within 
the track of the rack-mount rails. If the ears 
were mounted, screw the mounted ears into 
the rack to lock unit into position. (See the 
installation sheet located in the box marked, 
“Accessories.”)

Note:

 Avoid placing other components directly 

on top of or behind the unit. Leave at least one 
inch of space on all sides to allow for proper 
air ventilation. Do not block the fan.

Connecting the Battery

The RLC-1080 is shipped with front bezel of the 
unit unattached and with the internal battery 
pack disconnected. 

Connect the internal battery pack and attach 
the front bezel as follows:

1.  Remove the battery retaining bar.

2.  Push the Battery Wire Connector into the 

hole located at the left of the Battery Pack. 
Check to be sure that the connector is securely 
connected by gently pulling on the wire to 
see if it is attached to the connector.

3.  Install the battery retaining bar.

4.  Install the front Bezel by aligning the four pins 

located on the back-side of the Bezel to the 
holes at the left and right sides of the unit. 
Gently push the front Bezel onto the unit.

System Test

Before connecting equipment to the RLC-1080 
perform a System Test to be sure that the unit is 
functioning properly. Connect the AC Power Cord 
to the rear panel. Press the front panel power 
switch. Once power is applied to the unit, the 
display shows the following screen.

�������������������

���������������

This screen is displayed for a short period of time. 
It is followed by other screens that show model 
information, outlet delay operation, battery self-
test with results and external battery presence. 
Finally, the preceding screen is displayed.

Firmware Version screen

 shows the version 

of the firmware that is installed in the unit. (

Note:

 

The screen on your unit may appear different 
from the one illustrated below, depending on 
the firmware version.)

��������������������

DELAYED OUTLET1: ON; DELAYED OUT-

LET1: OFF screen

 shows that power is avail-

able to the device (Tuner or Auxiliary component) 
that is connected to the rear-panel outlet marked 

Delayed 1

.

It also shows that power is not yet available to 
the devices that are connected to rear-panel 
outlets marked 

Delayed 2

 (Subwoofer and/or 

Amplifier). Power to 

Delayed 2

 devices will 

be available after the factory preset delay (5 
seconds) has elapsed. See the 

Setting Up the 

RLC-1080

 section of this manual to change 

the delay period. Once power is available for 

Delayed 2

 devices, the screen will change to 

DELAYED OUTLET2:ON.

������������������

�������������������

Summary of Contents for RLC-1080

Page 1: ...RLC 1080 Power Conditioner Owner s Manual To register your purchase now go to www rotel com ...

Page 2: ...bend in the power cords which may break the wire strands of the cord Although this device provides protection against electrical surges when connecting an outside antenna or cable system to devices connected to this device ensure the antenna or cable system is grounded so as to provide additional protection against voltage surges and static charges in accordance with Section 810 of the National El...

Page 3: ...3 English Front and Rear Panel Controls and Connections ...

Page 4: ...ections 3 About Rotel 4 Getting Started 4 Features 5 Parts List 5 A Few Precautions 5 Power Capacity 5 Placement 5 Front Panel 6 ON BATTERY Status Indicator 1 6 DELAYED 1 Status Indicator 2 6 DELAYED 2 Status Indicator 3 6 REGULATING Status Indicator 4 6 Vacuum Fluorescent Display 5 6 OVERLOAD Status Indicator 6 6 FILTERING Status Indicator 7 6 LINE OK Status Indicator 8 6 LOW BATTERY Status Indic...

Page 5: ...r cause the building circuit breaker to trip Parts List The RLC 1080 Power Conditioner includes the parts listed below If any items are missing please contact your authorized Rotel dealer 1 Power Conditioner with Battery Backup bat tery pack included 1 Front Display Panel Bezel 1 Input Power Cord 3 Coaxial Patch Cables 1 DC Trigger Cable 1 PowerChute Personal Edition Software CD 1 USB Interface Ca...

Page 6: ...to maintain safe voltage conditions for the connected components or the unit is operating on battery power due to a power outage or extreme voltage level conditions LOW BATTERY Status Indicator 9 When lit orange this indicates the Battery Pack charge level is low This should occur only after the RLC 1080 has been running on battery power for a period of time The user can set the unit so this indic...

Page 7: ... reset the Circuit Breaker simply push the button in Caution When resetting the Circuit Breaker push the button in quickly and release it Do not hold the Circuit Breaker button in Doing so may result in equipment damage SYSTEM GROUND Screw o Provides for the connection of grounding wires from all of your equipment Grounding all your equipment to a single terminal prevents ground loop problems that...

Page 8: ...lock the fan Connecting the Battery The RLC 1080 is shipped with front bezel of the unit unattached and with the internal battery pack disconnected Connect the internal battery pack and attach the front bezel as follows 1 Remove the battery retaining bar 2 Push the Battery Wire Connector into the hole located at the left of the Battery Pack Check to be sure that the connector is securely connected...

Page 9: ...the AVR is active SYSTEM LOAD XXXW LOAD XXX This screen shows the power load of the connected equipment in watts as well as a percentage of the total allowable load connected to the unit Loads less than 5 of the rated power 50 watts are displayed as 5 EST RUNTIME XHRS FUEL XXX This screen shows the Estimated Runtime in hours as well as the Fuel capacity of the internal battery pack as a percentage...

Page 10: ... designed for certain type of components It is recommended that you connect your A V components to the power outlets that are designed for that type of unit For more information see the AC Power Outlets section of this manual Connect the ground connector of each component in the system to the SYSTEM GROUND terminal on the RLC 1080 This will eliminate ground loops thus prevent the audible hum that ...

Page 11: ...Y IF XXXV Setting Display example not shown This lets you set a low voltage threshold for the unit If the power input voltage goes down to the level set on this display screen the RLC 1080 switches to Internal Battery power The input voltage when this happens can be set from 90 to 100 volts OUTLET DELAY1 and OUTLET DELAY2 Setting Only the Outlet Delay1 display screen is shown This lets you set the...

Page 12: ...press the Status button until the desired screen is displayed Then press and hold the Status button down until the screen displays CURRENT SCREEN IS SAVED AS DEFAULT Troubleshooting The VFD screen will display any faults or warn ing conditions that occur along with a message explaining what action to take If ever in doubt as to what action to take please contact your authorised Rotel dealer or Rot...

Page 13: ... Car tridge part RBC63 canbeorderedfromyourau thorized Rotel dealer or Rotel Technical Support at techsupport rotel com or 800 370 3741 Limited Warranty Rotel warrants this product to be free from defects in materials and workmanship for a period of two years from the date of purchase Rotel s obligation under this warranty is limited to repairing or replacing at its own sole op tion any such defec...

Page 14: ... 90 Capacity 8 hrs Battery Service User replaceable Hot swappable Battery Life 2 5 Years Depending on use environment and temperature Battery Runtime 20 minutes half load or 7 5 minutes full load Actual runtimes are determined by load battery charge level battery health and quantity of batteries installed SURGE PROTECTION Let Through Voltage Rating 40V Data Line Protection Jacks RJ45 COAX 3 pair s...

Page 15: ......

Page 16: ...rd Street North Reading MA 01864 2699 USA Phone 1 978 664 3820 Fax 1 978 664 4109 Rotel Europe Dale Road Worthing West Sussex BN11 2BH England Phone 44 0 1903 221 761 Fax 44 0 1903 221 525 Rotel Deutschland Vertrieb B W Group Germany GmbH Kleine Heide 12 D 33790 Halle Westf Deutschland Tel 05201 87170 Fax 05201 73370 E Mail info bwgroup de www rotel hifi de www rotel com ...

Reviews: