6
x
Technical data
FA ROTEX Solaris DrainBack - 09/2016
27
6
Technical data
6.1
Product Fiche
Energy labelling Regulation: (EU) 811/2013
Ecodesign Regulation: (EU) 813/2013
6.2
General technical information
Solar devices
pumps + controls
/ Model names
RPS4
Auxiliary
Solpump
[W]
37.3
Solstandby
[W]
2
Annual auxiliary electricity
consumption Qaux
[kWh/a]
92
Details and precautions on installation, maintenance and assembly can be found in the installation and or operation manuals. Energy
labels and product fiches for addition combinations, packages and other products can be found on www.rotex-heating.com.
Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825.
This data is for comparison of Energy efficiencies according to Energy label directive 2010/30/EC, for correct selection of products
for your application, contact your dealer. Depending on your application and the product selected an additional supplementary heater
may have to be installed.
Tab. 6-1 Characteristic data for determining the values for energy efficiency identification
Unit
Solaris flat solar panel
V21P
V26P
H26P
General
Dimensions L x W x H
mm
2000 x 1006 x 85
2000 x 1300 x 85
1300 x 2000 x 85
Frame material
–
Aluminium
Solar panel weight
kg
35
42
42
Solar panel content
l
1.3
1.7
2.1
Inclination angle
°
15-80
Absorber
Material
–
Aluminium
Thickness
mm
0.4
Coating
–
MIRO-THERM
Connection to pipe register
–
Laser welded
Pipe register material
–
Copper
Pipe register shape
–
Harp
Glass
Material
–
Single-pane safety glass
Thickness
mm
3.2
Min. hail resistance
–
HW 3
Reference area
Gross surface area
m
2
2.01
2.60
Aperture surface area
m
2
1.80
2.36
Absorber surface area
m
2
1.80
2.36
Heat insulation
Material
–
Mineral wool
Thermal conductivity
W/(m K)
0.037
Thickness [mm]
mm
50