3
x
Installation
23
FA ROTEX Solaris RPS3 25M - 03/2010
Operation
– The solar return is taken from the solar zone of one of the connected hot water storage tanks via the return connection pipe
(Image 3-32, Pos. 5).
– The common return is pumped to the collector array via the pump(s) (Image 3-32, Pos. 4) controlled by the Control unit RPS3
25M.
– The water is heated in the collector array and is fed as the solar flow into the DHW storage tank via the flow distributor pipe
1/1-3
Hot water storage tank
2
Non-pressurised area
3
Collector array
4
Circulation pump (bottom) and
optional booster pump (top)
5
Solaris return flow connection pipe (non-pressurised area)
6
Solaris flow manifold
7
Solaris return line
8
Solaris flow line
AGL
Equalising pipe
AGLE
Equalising pipe extension kit
CON RA 25M
connection set (return)
CON SX
Storage tank extension kit
CON SXE
Storage tank extension kit 2
CON ... (A) Return connection pipe from
storage tank extension kit
CON ... (B) Flow manifold from storage tank extension kit
FLS
FlowSensor
FLG
FlowGuard
∆
H
Difference in level in non-pressurised storage tank area
Illustration 3-32 Operating principle of the common return flow pipe