DESCRIPTION 

Combining small size and versatility, the newly redesigned Roth power supply MINI is an ideal choice 
for any researcher. Capable of providing constant current or constant voltage in 1 mA or 1 V steps, 
the microprocessor controlled unit is perfectly suited to run both vertical polyacrylamide and horizontal 
agarose electrophoresis experiments. Continuous or timed operations are easily performed using the 
simple and user-friendly interface. The Roth power supply MINI features 2 electrode pairs, allowing for 
2 gels to be run simultaneously, saving both time and valuable bench space. With a universal voltage 
rating, the Roth MINI is also designed and constructed to the most rigorous safety standards. This 
makes it an excellent choice for education or personal use. 

 
 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 
 
 

FEATURES 

 

Compact size 

 

Power capacity 

 
 
 
 
 
 
 

 

Constant Voltage or Constant Current operation 

 

1 V step voltage selection; 1 mA step current selection 

 

Timer 

 

No load detection 

 

Shrouded plugs and sockets 

 

Two pairs of outlet terminals 

 

Output voltage stability 

 

Economic choice for larger horizontal electrophoresis & 10 x 10 cm vertical electrophoresis 

 

New polycarbonate housing and aluminum bottom plates; new exterior design

 

Roth MINI 

 
120W, 400mA, 500V 

Front view

 

ON/OFF  
Switch 

Fan 

Rear view

 

Main power socket 
& Fuse holder 

Summary of Contents for MINI

Page 1: ...ully before operating this equipment 1 Read and follow the manual instructions carefully 2 Do not alter the equipment Failure to follow these directions could result in personal and or laboratory hazards as well as invalidate the equipment warranty 3 Use a properly grounded electrical outlet of correct voltage and current handling capacity 4 Disconnect from the power source before maintenance and ...

Page 2: ...ight of the power switch is on 3 WAIT at least 5 seconds after stopping a run before handling output leads or connected apparatus 4 ALWAYS make sure that your hands work area and instruments are clean and dry before making any connections or operating the power supply 5 ONLY connect the power cord to a properly grounded AC outlet Avoiding Damage to the Instrument 1 Do not attempt to operate the de...

Page 3: ...t into a municipal trash bin when this unit has reached the end of its lifetime To ensure utmost protection of the global environment and minimize pollution please recycle this unit Caution Warning Indicates a hazardous situation which if not avoided could result in death or serious injury Max voltage 500 V Max current 400 mA Max watt 120 W Encountering Problems Check the troubleshooting section C...

Page 4: ...multaneously saving both time and valuable bench space With a universal voltage rating the Roth MINI is also designed and constructed to the most rigorous safety standards This makes it an excellent choice for education or personal use FEATURES Compact size Power capacity Constant Voltage or Constant Current operation 1 V step voltage selection 1 mA step current selection Timer No load detection S...

Page 5: ...t Constant V or mA with automatic crossover During constant mode not adjusted parameters are automatically set to maximum Programs Manuell adjustable mode Constant Mode 2 step program editable 30 programs each with up to 6 steps editable Program Mode 2 step program pre assigned Pre assigned programs for different applications Typical running condition Mode Outlets parallel socket pairs 2 4 mm 5 4 ...

Page 6: ... 1 Before operation press MODE to set the parameters of Voltage Current and Time of Step 1 and 2 LED light indicates your current parameter For example if you are setting a value for Voltage the Voltage LED will be lit 2 Two step buttons are available for you to select the step and to check the parameters of voltage current and time of each step User will press STEP 1 and STEP 2 buttons mainly to ...

Page 7: ...example to operate under constant voltage adjust current to max before running constant voltage and vice versa 1 Adjust the output value by pressing the or button 2 After adjusting your constant mode output value switch to the other parameter and set it to maximum 3 Timer Setting After setting the current or voltage output value press MODE to switch to time setting mode then press key or key to ad...

Page 8: ...making sure the tape is removed from the pre cast gel that the buffers are prepared correctly and the recommended volume of buffer is added to the electrophoresis unit Error Message Cause Solution Current exceeds the maximum output for the power supply 400 mA Check if the buffer concentration or molarity is appropriate Excessive buffer concentration or molarity may increase conductivity To clear t...