8
SCOPE OF USE
Proceed as follows to connect the appliance to a gas cylinder:
- Ensure that all valves are closed.
- Check that the seal between the regulator and the gas container are in place and in good condition
before connecting to the gas container. Depending on the version / country, the seal may be located
in the pressure regulator connection, in the gas cylinder connection or in both connections. In case of
doubt, please contact your local gas dealer.
- Check the condition of the hose and regulator each time before using the burner. Do not use a hose
or regulator that is damaged or worn.
- Connect the pressure regulator to the gas cylinder. Ensure that the direction of rotation of the thread
is correct (there may be differences according to country).
- Install the hose failure safety device, if available.
- Connect the gas hose to the pressure regulator and to the appliance. The hose end connector and
the appliance connector have left-handed threads.
- Fit the required attachment.
- Tighten the connection with the burner wrench (supplied). Do not exert excessive force to prevent
over-tightening or damaging the threads.
- Open the cylinder valve. Ensure that all the connections are tight. Use a leakage detection spray or
soapy water for this purpose. The connections may have to be re-tightened.
- Do not use the device if there is a leak in the system.
Proceed as follows to ignite and adjust the flame:
- First open the cylinder valve and subsequently the regulator valve on the handle. Observe the marked
direction of rotation (+: anti-clockwise; -: clockwise).
- When using a freshly filled gas cylinder and especially when using smaller burners it is important to
wait a short time until any air in the system clears.
- Apply a flame to the lower edge of the burner opening (with the safety lighter supplied of with a gas
ligher).
CONNECTING TO A GAS CYLINDER
LIGHTING AND EXTINGUISHING THE BURNER
TECHNICAL SPECIFICATIONS FOR TURBO BRAZING SET 030900
Flame temperature:
up to 2000°C
Working temperature
up to 800°C
Use the working temperature to determine suitable fluxes, soldering and
brazing rods for the ROTHENBERGER INDUSTRIAL range.
Gas type
Propane, propane/butane mix
Appliance category:
Propane vapour pressure
Working pressure:
max. 4 bar, 8 kg/h
Injector diameter (Handle):
0.25 mm
Gas consumption / performance
28 mm Turbo-Burner: > 540 g/h / 7.56 kW / 0.4 mm
Injector diameter (burner)
22 mm Turbo-Burner: > 260 g/h / 3.64 kW / 0.35 mm
22 mm Brazing burner: > 260 g/h / 3.64 kW / 0.35 mm
14 mm Point burner: > 160 g/h / 2.24 kW / 0.1 mm
17 mm Soldering burner: > 200 g/h / 2.8 kW / 0.25 mm
Burner markings
28 mm Ø Turbo: 22 mm, 22 mm Ø Turbo: P22RT
22 mm Ø: P22R, 14 mm Ø: P14R, 17 mm Ø: P17R
Burner handle
ROTHENBERGER Industrial P
The burner may not be used without a constant pressure regulator fitted. This appliance
shall only be used with LPG refillable cylinders and only in the open or in well-ventilated
rooms. Keep children away from the device!
030900_Anleitung_26 Sprachen:PRINT 19.10.2016 10:21 Uhr Seite 8