ENGLISH
27
5.
Schematic of a heating system
1 micro-filter
2 TW- distributor
3 Pipe disconnector
4 Cleaning compressor
5 Floor heating circuit
6 Connection hose
7 Drain hose
8 Stop valve
9. Drainage
6.
Press the ON/OFF button. The compressor fills the pressure vessels automatically.
7.
Press the program button “Water and air (pulsing)”.
When the stop valves are opened, the flow rate is displayed. In the rinse compressor, a
continuous air blast will be mixed with the rinse water. For stubborn grime, the button
“Water and air (continuous)” can additionally be pressed.
8.
The rinsing process in a floor heating system is over when no more sludge or algae
particles are visible in the drain hose.
9.
After rinsing, shut off the water supply and the rinse compressor. Then disconnect the
device from the power supply.
10.
Finally, the system must be checked for leaks and the heating system aired out.
11.
Sequentially fill all heating strands with heater protection fluid (follow the product’s
instructions).
5
Installation and maintenance instructions for compressor
Starting Operation:
-
Check nameplate to ensure that indicated voltage agrees with supply voltage.
-
Insert plug in respective socket.
The plug coming with the equipment is a VDE 16A.
Operation of the compressor is automatically controlled by the pressure control, which
switches the compressor off once pressure in the tank has reached its maximum, while it
starts again when it has fallen to its minimum.
Proper automatic operation of the compressor is indicated by a compressed air blast when
the motor stops.
Cleaning compressor
Boiler
Drinking water
Return pipe
Drain
Flow pipe