ENGLISH
13
2
Technical Data, see „technical data“ book
3
Function of the Unit
3.1
Overview (ill. A)
1
Trimmer unit
8
Main clamp
Version A
2
Heating element
8.1
Adjusting nut
3
Machine housing
8.2
Tensioning screw
4
Movable table
9
Main clamp
Version B
5
Clamping lever
9.1
Clamping insert, bracket
6
Grip bar
10
Support brackets
7
Safety catch
11
Knob
Welded joints for house installations, chimney renovations and roof drainage systems made of
PE, PVDF and PP pipes with outer diameters of 40 -
160mm/ 1“- 5“ can be safely produced with
the machine.
Depending on the version (
Version A
= clamping plates, knee lever version,
Version B
=
clamping plates, screw version), clamping elements can be used instead of the support forks for
the exterior clamping positions. Threads are provided for this purpose in the machine base and
in the movable table.
3.2
Operating instructions
In accordance with national or EU ordinances and guidelines, e. g. DVS 2212,
Section I, only duly qualified and authorised personnel are allowed to operate the
ROWELD welding machines!
Only trained and authorised welders are allowed to operate the machine!
3.2.1 Putting into operation
Please read through the operating instructions and safety instructions atten-
tively before you put the butt fusion welding machine into operation!
Do not use the heating element in explosive environments or bring it into
contact with easily flammable materials!
Put the machine on a level, solid surface.
Pull the knob (11), swing the machine upward, and allow the locking bolts to click in.
Make sure that both bolts are engaged in the holes in the frame!
Pull the trimmer lock (7) to the front and swivel the trimmer (1) to the back.
Swivel heating element (2) to the back.
Connect power plug of trimmer unit (1) and heating element (2) to the power supply stated
on the type plate.
The red diode “Stand by“ lights up. That is: there is a voltage being applied. Switch on the heater
element using the large pushbutton (lights up green) and select the desired temperature (160°C
to 285°C) using the “+“ or “-“ button.
Heating up of the heater element is displayed by a yellow diode on the heater element. A hori-
zontal bar also appears on the temperature indicator. The yellow diode goes out shortly before
reaching the set temperature (tol/-3°C) and the green one lights up. After a further 10
minutes the heating element is ready to use. Check the temperature using a temperature meas-
uring instrument.
Setting the off-set:
press the “+“ and “-“ button at the same time. The heater element can subse-
quently be calibrated using one of these buttons and an external temperature measuring instru-
ment.