RFD OPERATOR MANUAL
3-20
3. SYSTEM SPECIFICATIONS.
3.1. RADIO.
CARRIER
FREQUENCY
135 - 174 MHz *
OPERATING
TEMPERATURE
RANGE
-30ºC to 60ºC
-22ºF to 140ºF
FCC
Pending
<freq. diff. 1300 HZ (±650)
CONTROLLER UNIT
DETONATOR UNIT
FREQUENCY
STABILITY
±5PPM OR
(0.00005%)
FREQUENCY
STABILITY
±5PPM OR
(0.00005%)
MODULATION
10K6F2D (AFSK)
MODULATION
10K6F2D (AFSK)
TRANSMIT
POWER
5 Watts
TRANSMIT
POWER
100 milliwatts
OPERATING
POWER
12 VDC
OPERATING
POWER
7.2 VDC
TRANSMISSION
RANGE
5 miles (line-of-
site)**
TRANSMISSION
RANGE
Approximately 1,000
feet
RECEIVER
SENSITIVITY
12 dB Sinad at
0.28uV
RECEIVER
SENSITIVITY
12 dB Sinad at
0.28uV
(*)
The Production Unit Frequency Designation will be provided in the contract.
(**)
Typical transmission range, based on frequency used and terrain. Frequencies
under 150 MHz typically have a range of at least 4 miles,
Summary of Contents for REMOTE FIRING DEVICE
Page 6: ...RFD OPERATOR MANUAL vi ...
Page 12: ...RFD OPERATOR MANUAL 1 3 Figure 1 1 RFD System ...
Page 15: ...RFD OPERATOR MANUAL 2 6 Figure 2 1 RFD System ...
Page 27: ...RFD OPERATOR MANUAL 2 18 Figure 2 9 Detonator Antenna Battery Charger Connection ...
Page 49: ...RFD OPERATOR MANUAL 8 40 Figure 8 3 Detonator Unit Tilted ...
Page 50: ...RFD OPERATOR MANUAL 8 41 Figure 8 4 Antenna Radiation Pattern ...