RFD OPERATOR MANUAL
4-25
4.2.4.
Plug the AC cord into a 110 VAC 60 Hz outlet. The Battery Charger
Assembly will operate from 90-135/180-270 VAC, 47-63 Hz.
4.2.5.
Connect each Detonator Unit and the Controller Unit to the Battery Charger
Assembly. The Controller Unit can be connected to any of the nine cables.
4.2.6.
Open the vent on each Detonator Unit and the Controller Unit.
4.2.7.
Turn on the power switch on the Battery Charger Assembly.
4.2.8.
The CHARGE light for each connected unit will flash for approximately 5
seconds. The flashing CHARGE light indicates that rapid charging is pending.
4.2.9.
In normal operation, the CHARGE light will be on solid after 5 seconds has
passed. The solid CHARGE light indicates that the battery is being rapid charged.
4.2.10.
The battery must be within the temperature range 32 ºF and 104 ºF for rapid
charging to occur. If the battery pack is not within temperature range for rapid charging,
the CHARGE light will continue to flash beyond 5 seconds. While the CHARGE light is
flashing, the battery pack is being slow charged.
4.2.11.
If the detected battery voltage is less than 6 volts for Detonator Units and 10
volts for Controller Units, the battery will be slow charged until the voltage is high
enough for rapid charge. If the battery pack is defective and the voltage does not rise to
the correct level, for rapid charge, the Battery Charger Assembly remains in slow
charge mode. In that case the CHARGE light will continue to flash.
4.2.12.
When rapid charging terminates, the DONE light will be on steady, and the
CHARGE light will be turned off.
4.2.13.
Rapid charging terminates when the charger detects the battery pack is
charged. Rapid charging will also terminate after 90 minutes, or if the battery pack
temperature is out of range.
4.2.14.
If a Controller Unit or Detonator Unit is left turned on beyond the low battery
point, the battery pack may not fully charge before the 90 minute rapid charge time limit
expires. In that case, charge the battery pack again.
4.2.15.
Close the vent on each Detonator Unit and the Controller Unit
4.3. BATTERY
DISCHARGING.
4.3.1.
Turn off the power switch on the Battery Charger Assembly.
4.3.2.
Plug the AC cord into a 110VAC 60Hz outlet. The Battery Charger Assembly
will operate from 90-135/180-270 VAC, 47-63 Hz.
Summary of Contents for REMOTE FIRING DEVICE
Page 6: ...RFD OPERATOR MANUAL vi ...
Page 12: ...RFD OPERATOR MANUAL 1 3 Figure 1 1 RFD System ...
Page 15: ...RFD OPERATOR MANUAL 2 6 Figure 2 1 RFD System ...
Page 27: ...RFD OPERATOR MANUAL 2 18 Figure 2 9 Detonator Antenna Battery Charger Connection ...
Page 49: ...RFD OPERATOR MANUAL 8 40 Figure 8 3 Detonator Unit Tilted ...
Page 50: ...RFD OPERATOR MANUAL 8 41 Figure 8 4 Antenna Radiation Pattern ...