RFD OPERATOR MANUAL
5-29
5. OPERATIONAL PROCEDURES.
WARNING
Use of this system and its components must be restricted to personnel
qualified and experienced in the field of explosives and detonating devices. Under no
circumstances shall untrained personnel attempt to use this manual as a text for self-
teaching.
WARNING
Employ standard blasting system safety standards when using this
equipment with explosives.
CAUTION
All units must be thouroughly tested and the batteries fully charged prior
to operational use.
5.1. READY THE SYSTEM AT SITE.
5.1.1.
Detonator Units. Select the number of Detonator Units required for the
operation. Remove the dust cover from the antenna / battery charger connector. Install
the Antenna Assembly on to the antenna / battery charger connector. This will turn on
the Detonator Unit. The yellow ON/LOW BATT light and green SAFE light will be turned
on. The green SAFE light will be on whenever the Detonator Unit is turned on and it is
Disarmed. In the Disarmed state, the firing capacitor charge circuit is disabled, the
binding posts are electrically isolated from the firing capacitor, and the binding posts are
shunted to each other. If the yellow ON/LOW BATT light is flashing, the Detonator Unit
battery is low and should be recharged before use.
WARNING
Do not connect a blasting cap to a Detonator Unit unless the green
SAFE light is on, the red ARMED light is off, and the yellow ON/LOW BATT light is on
steady. This indicates there is no voltage on the binding posts, the binding posts are
electically isolated from the firing capacitor, the binding posts are shunted to each other,
and the battery is not low.
5.1.2.
Open and close the vent on each Detonator Unit and the Controller Unit to
equalize the case pressure. Unscrew the vent one revolution to open.
5.1.3.
Remove the dust cover from the antenna / battery charger connector of the
Controller Unit. Install the Antenna Assembly on to the antenna / battery charger
connector. This will enable the keypad on the Controller Unit.
WARNING
The Controller Unit has a 5 watt output power level (5 mile transmit
range). The Controller Unit should be considered DANGEROUS and NEVER be
operated within 100 feet (minimum) of blasting caps, wires connected to blasting caps,
or other electrically initiated explosives devices. Do NOT apply power to the Controller
Unit unless the operator is at least 100 feet from blasting caps, wires connected to
blasting caps, or explosives.
Summary of Contents for REMOTE FIRING DEVICE
Page 6: ...RFD OPERATOR MANUAL vi ...
Page 12: ...RFD OPERATOR MANUAL 1 3 Figure 1 1 RFD System ...
Page 15: ...RFD OPERATOR MANUAL 2 6 Figure 2 1 RFD System ...
Page 27: ...RFD OPERATOR MANUAL 2 18 Figure 2 9 Detonator Antenna Battery Charger Connection ...
Page 49: ...RFD OPERATOR MANUAL 8 40 Figure 8 3 Detonator Unit Tilted ...
Page 50: ...RFD OPERATOR MANUAL 8 41 Figure 8 4 Antenna Radiation Pattern ...