RFD OPERATOR MANUAL
ix
WARNING
Do not connect a blasting cap to a Detonator Unit unless the green
SAFE light is on, the red ARMED light is off, and the yellow ON/LOW BATT light is on
steady. This indicates there is no voltage on the binding posts, the binding posts are
electically isolated from the firing capacitor, the binding posts are shunted to each other,
and the battery is not low.
WARNING
Ensure that blasting caps are not connected to any of the Detonator
Units during bench test.
WARNING
This is a sensitive electronic radio system and it may be damaged.
WARNING
Detonator Units have been tested and are safe to use near explosives
and blasting caps. The low level of transmit power (less than 100 milliwatts) used by
the Detonator Unit will NOT detonate blasting caps, even if they are directly connected
to the Detonator Unit's antenna terminals. The Detonator Unit transmission range is
limited - approximately 1,000 feet. The Detonator Units will receive and will act upon
commands from the Controller Unit which may be located in the line of site up to 5 miles
away. The controller Unit need not and may not receive verification from a Detonator
Unit which is more than 1,000 feet away.
CAUTION
Do not assume the Disarm command has been received by the
Detonator Unit unless DISARMED status is confirmed with a steady DISARMED light
for that Detonator Unit on the Controller Unit display panel. If distance appears to be
the problem, move closer to the Detonator Unit following standard procedures for this
type of situation. The “STATUS” and/or “DISARM” switches may be pressed repeatedly
as the Detonator Unit is approached. Maintain a safe distance from the Detonator Unit.
Do not approach the Detonator Unit until Disarmed status is confirmed with a steady
DISARMED light for that Detonator Unit on the Controller Unit display panel. Under no
conditions should the “FIRE” switch be pressed as the Detonator Unit is approached.
Do not bring the Controller Unit closer than 100 feet to blasting caps, wires connected to
blasting caps, or other explosives.
CAUTION
All units must be thouroughly tested and the batteries fully charged
prior to operational use.
CAUTION
Unequal air pressure inside the Controller Unit may affect the
operation of membrane switch keypad. Extreme pressure differentials may irreversibly
damage the keypad and/or cases.
CAUTION
Vents in all units should be momentarily opened and closed
immediately before use.
CAUTION
Do not open a vent if there is water on or near the vent. Take
necessary precautions to ensure water does not enter the vent.
CAUTION
Do not use any component that is damaged, suspected of being
damaged, or is not able to operate as designed. The safety of the operation could be
compromised.
Summary of Contents for REMOTE FIRING DEVICE
Page 6: ...RFD OPERATOR MANUAL vi ...
Page 12: ...RFD OPERATOR MANUAL 1 3 Figure 1 1 RFD System ...
Page 15: ...RFD OPERATOR MANUAL 2 6 Figure 2 1 RFD System ...
Page 27: ...RFD OPERATOR MANUAL 2 18 Figure 2 9 Detonator Antenna Battery Charger Connection ...
Page 49: ...RFD OPERATOR MANUAL 8 40 Figure 8 3 Detonator Unit Tilted ...
Page 50: ...RFD OPERATOR MANUAL 8 41 Figure 8 4 Antenna Radiation Pattern ...