54
July 2017
IMO_457_DE_v0
Roto Safe C | C600 | C600 – Tandeo | H600
Subject to change.
Maintenance
Roto Safe C performance test – Cylinder-operated multi-point locking systems
When the door is open
REQUIREMENT
The door and door frame must be vertical for the performance test.
Open the door.
Check that the fixing screws are fitted securely.
Use a screwdriver to check that all fixing screws have been tightened.
Screws must not be over-tightened.
Check that the lever handle is working properly.
Push the lever handle all the way down and release.
> The lever handle must automatically return to the initial position.
Check that the latch is working properly.
Push the lever handle all the way down.
> The latch must retract.
> When pushed down, the latch may protrude over the lock faceplate of the lock by a maximum of 2 mm.
Release the lever handle.
> The latch must extend fully.
Turn the key in the profile cylinder in the unlocking direction.
> The latch must retract fully.
Check that the deadbolt is working properly.
Turn the key in the profile cylinder by two rotations in the locking direction.
(One turn of the key provides push-back safeguard security, the door is locked after two turns of the key.)
> The deadbolt must be extended fully (20 or 11 mm).
> All additional locks must be in the locking position.
> It must be possible to remove the key.
Have malfunctions remedied by a specialist company.